SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF SULFIDE WITH IRON(III) AND NITRILOTRIACETIC ACID BY FLOW-INJECTION

被引:12
|
作者
KESTER, MD [1 ]
SHIUNDU, PM [1 ]
WADE, AP [1 ]
机构
[1] UNIV BRITISH COLUMBIA,DEPT CHEM,AUTOMATED CHEM ANALYSIS LAB,VANCOUVER V6T 1Z1,BC,CANADA
关键词
D O I
10.1016/0039-9140(92)80036-D
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A manual colorimetric method for determination of sulfide has been adapted to flow injection, systematically optimized, and more fully characterized. Its intended application is for measurement of sodium sulfide reagent strength in pulp process streams, and sulfide contamination in effluent from Kraft pulp mills. In the flow-injection method developed, a sample solution containing sulfide is reacted with a mixture of iron(III) and nitrilotriacetic acid under ammoniacal conditions. The absorbance of the intensely-colored green product of this reaction is measured at 636 nm. Excess sulfite is present as a color stabilizer. A linear dynamic range of 20-100 ppm sulfide is readily achieved; the relative standard deviation is less than 1.2% (n = 10) throughout this range, and 0.37% (n = 10) midrange at 60 ppm. The usable dynamic range is 8-250 ppm sulfide. Long-term stability of the method is ensured by periodically performing an automatic cleaning cycle using a hydrochloric acid wash solution. This prevents tube discoloration and removes any precipitates which are for-med under strongly alkaline conditions. The sample throughput rate is at least 30/hr, given alternate acid wash cycles.
引用
收藏
页码:299 / 312
页数:14
相关论文
共 50 条
  • [1] FLOW-INJECTION SPECTROPHOTOMETRIC CATALYTIC METHOD FOR THE DETERMINATION OF RUTHENIUM(III)
    ALMUAIBED, AM
    TOWNSHEND, A
    MICROCHEMICAL JOURNAL, 1993, 48 (02) : 210 - 214
  • [2] USE OF ACETOHYDROXAMIC ACID IN THE DIRECT SPECTROPHOTOMETRIC DETERMINATION OF IRON(III) AND IRON(II) BY FLOW-INJECTION ANALYSIS
    SENIOR, AT
    GLENNON, JD
    ANALYTICA CHIMICA ACTA, 1987, 196 : 333 - 336
  • [3] Spectrophotometric flow-injection method for determination of sorbic acid in wines
    Department of Analytical Chemistry, Faculty of Sciences, University of Málaga, 29071 Malaga, Spain
    Lab Rob Autom, 5 (299-303):
  • [4] Spectrophotometric flow-injection method for determination of sorbic acid in wines
    Molina, AR
    Alonso, EV
    Cordero, MTS
    de Torres, AG
    Pavón, JMC
    LABORATORY ROBOTICS AND AUTOMATION, 1999, 11 (05) : 299 - 303
  • [5] THE SPECTROPHOTOMETRIC DETERMINATION OF IRON(III) IN A FLOW-INJECTION SYSTEM WITH A MIXED-SOLVENT
    CARDWELL, TJ
    CARIDI, D
    CATTRALL, RW
    HAMILTON, IC
    ANALYTICA CHIMICA ACTA, 1987, 192 (01) : 129 - 132
  • [6] SPECTROPHOTOMETRIC DETERMINATION OF PHENOLS BY FLOW-INJECTION METHOD
    KOJLO, A
    WOLYNIEC, E
    PUZANOWSKATARASIEWICZ, H
    POLTORAK, J
    GRUDNIEWSKA, A
    CHEMIA ANALITYCZNA, 1991, 36 (5-6): : 868 - 877
  • [7] Flow-injection spectrophotometric determination of yttrium with Arsenazo III
    Grudpan, K
    Praditweangkum, W
    Sooksamiti, P
    Edwards, R
    LABORATORY ROBOTICS AND AUTOMATION, 1999, 11 (05) : 279 - 283
  • [8] Sequential Determination of Iron(II) and Iron(III) in Pharmaceutical by Flow-Injection Analysis with Spectrophotometric Detection
    Ensafi A.A.
    Chamjangali M.A.
    Mansour H.R.
    Analytical Sciences, 2004, 20 (4) : 645 - 650
  • [9] Spectrophotometric determination of iron with ferrozine by flow-injection analysis
    PascualReguera, MI
    OrtegaCarmona, I
    MolinaDiaz, A
    TALANTA, 1997, 44 (10) : 1793 - 1801
  • [10] Sequential determination of iron(II) and iron(III) in pharmaceutical by flow-injection analysis with spectrophotometric detection
    Ensafi, AA
    Chamjangali, MA
    Mansour, HR
    ANALYTICAL SCIENCES, 2004, 20 (04) : 645 - 650