CONCENTRATION AND OR REMOVAL OF METAL-IONS USING A WATER-SOLUBLE CHELATING POLYMER AND A MICROPOROUS HOLLOW-FIBER MEMBRANE

被引:34
|
作者
TOMIDA, T
INOUE, T
TSUCHIYA, K
MASUDA, S
机构
[1] Department of Chemical Science and Technology, University of Tokushima
关键词
D O I
10.1021/ie00028a017
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Methods for concentrating and/or removing metal ions from dilute solutions using a water-soluble chelating polymer and a microporous hollow fiber were studied. Experiments were made with a model system of polyacrylic acid and Cu(II). In the once-through mode, where the metal solution flowed inside the fiber immersed in the polymer solution, concentrations of metal ions of as high as 80% in the sample solutions were deionized by use of a fiber of 1.2-m length and 0.8-mm inner diameter. In the circulating mode, where the polymer solution was circulated through the fiber immersed in the sample solution, the metal ions could be recovered from dilute solutions even when concentrations were much lower than those on the recovery side. The overall mass transfer coefficient obtained in this experiment was 10(-6)-10(-5) m/s. The methods reported here were demonstrated to be effective for concentrating and/or removing metal ions from dilute solutions.
引用
收藏
页码:904 / 906
页数:3
相关论文
共 50 条
  • [1] Concentration and/or removal of metal ions using a water-soluble chelating polymer and a microporous hollow fiber membrane
    Tomida, Tahei
    Inoue, Tatsuya
    Tsuchiya, Katsumi
    Masuda, Seizo
    Industrial and Engineering Chemistry Research, 1994, 33 (04): : 904 - 906
  • [2] CONCENTRATION OF COPPER(II) ION IN WATER USING A WATER-SOLUBLE CHELATING POLYMER AND A MICROPOROUS HOLLOW-FIBER
    TOMIDA, T
    INOUE, T
    FUJITA, K
    MASUDA, S
    CHEMISTRY LETTERS, 1994, (04) : 787 - 788
  • [3] Transient analysis of mass-transfer rate in recovering metal ions using a microporous hollow fiber membrane and a water-soluble chelating polymer
    Tomida, T
    Katoh, M
    Inoue, T
    Minamino, T
    Masuda, S
    SEPARATION SCIENCE AND TECHNOLOGY, 1998, 33 (15) : 2281 - 2293
  • [4] PREPARATION OF WATER-SOLUBLE CHELATING ANIMATED STARCH DERIVATIVES AND THEIR USE FOR THE CONCENTRATION OF METAL-IONS BY ULTRAFILTRATION
    OUIMINGA, SA
    BRANDEBOURGER, M
    CHAUFER, B
    DERATANI, A
    SEBILLE, B
    REACTIVE POLYMERS, 1987, 5 (02): : 111 - 122
  • [5] RECOVERY OF METAL-IONS FROM DILUTE-SOLUTIONS USING A WATER-SOLUBLE CHELATING POLYMER AND DIALYSIS MEMBRANES
    TOMIDA, T
    IKAWA, T
    MASUDA, S
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1993, 26 (05) : 575 - 577
  • [6] USING A MICROPOROUS HOLLOW-FIBER MEMBRANE TO SEPARATE VOCS FROM WATER
    SEMMENS, MJ
    QIN, R
    ZANDER, A
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1989, 81 (04): : 162 - 167
  • [8] REMOVAL OF ENDOTOXIN FROM WATER BY MICROFILTRATION THROUGH A MICROPOROUS POLYETHYLENE HOLLOW-FIBER MEMBRANE
    SAWADA, Y
    FUJII, R
    IGAMI, I
    KAWAI, A
    KAMIKI, T
    NIWA, M
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1986, 51 (04) : 813 - 820
  • [9] Detritiation of water using microporous hollow-fiber membranes
    Kelso, RC
    Ahmed, T
    Middlebrooks, EJ
    WATER ENVIRONMENT RESEARCH, 1997, 69 (02) : 180 - 187
  • [10] Effect of the polymer concentration on the interactions of water-soluble polymers with metal ions
    Rivas, BL
    Moreno-Villoslada, I
    CHEMISTRY LETTERS, 2000, (02) : 166 - 167