MAGNETIC-RESONANCE MEASUREMENT OF PULMONARY VENOUS FLOW AND DISTENSIBILITY

被引:2
|
作者
MOHIADDIN, RH
AMANUMA, M
LONGMORE, DB
机构
来源
AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY | 1992年 / 6卷 / 01期
关键词
MAGNETIC RESONANCE; PULMONARY VEIN; BLOOD FLOW; DISTENSIBILITY;
D O I
10.1159/000470320
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance velocity mapping was used to study the pulmonary venous flow pattern and to measure pulmonary venous flow volume in 10 normal subjects. Pulmonary venous flow showed a forward flow with two peaks, one during ventricular systole and another in diastole. A reversed flow during atrial systole was noticed. The flow pattern is understandable in relation to the dynamics of the left heart and is consistent with flow patterns obtained by other techniques. Right and left lower pulmonary venous flow was measured and corrected for body surface area. Flow (means +/- SD) in the right lower pulmonary vein was 13.0 +/- 3.7 ml/s/m2 and in the left 11.9 +/- 2.2 ml/s/m2. Distensibility of the pulmonary veins was studied from changes in the cross-sectional areas of pulmonary veins throughout the cardiac cycle. non-significant changes were demonstrated reflecting the non-distensible nature of these vessels. Magnetic resonance imaging provides a totally noninvasive technique for qualitative and quantitative examination of pulmonary venous flow which could be of clinical value in the assessment of both cardiac and pulmonary problems.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 50 条
  • [1] MAGNETIC-RESONANCE ASSESSMENT OF THE PULMONARY ARTERIAL TRUNK ANATOMY, FLOW, PULSATILITY AND DISTENSIBILITY
    PAZ, R
    MOHIADDIN, RH
    LONGMORE, DB
    EUROPEAN HEART JOURNAL, 1993, 14 (11) : 1524 - 1530
  • [2] NONINVASIVE MEASUREMENT OF AZYGOS VENOUS-BLOOD FLOW USING MAGNETIC-RESONANCE
    LOMAS, DJ
    HAYBALL, MP
    JONES, DP
    SIMS, C
    ALLISON, MED
    ALEXANDER, GJM
    JOURNAL OF HEPATOLOGY, 1995, 22 (04) : 399 - 403
  • [3] FLOW MEASUREMENT BY MAGNETIC-RESONANCE IMAGING
    BARTH, K
    DEIMLING, M
    FRITSCHY, P
    MUELLER, E
    REINHARDT, ER
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 535 : 261 - 267
  • [4] VISUALIZATION AND MEASUREMENT OF FLOW WITH MAGNETIC-RESONANCE IMAGING
    BARTH, K
    DEIMLING, M
    FRITSCHY, P
    LENZ, G
    MULLER, E
    REINHARDT, ER
    BIOMEDIZINISCHE TECHNIK, 1985, 30 (1-2): : 12 - 17
  • [5] THE MEASUREMENT OF FLOW USING MAGNETIC-RESONANCE IMAGING
    SMITH, MA
    TARNAWSKI, M
    WEST, DJ
    TAYLOR, G
    AYTON, VT
    GOSLING, RG
    MAISEY, MN
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 789 - 789
  • [6] MEASUREMENT OF BLOOD-FLOW BY NUCLEAR MAGNETIC-RESONANCE
    BATTOCLETTI, JH
    POSTGRADUATE MEDICINE, 1982, 72 (05) : 43 - &
  • [7] PULMONARY-ARTERY DISTENSIBILITY AND BLOOD-FLOW PATTERNS - A MAGNETIC-RESONANCE STUDY OF NORMAL SUBJECTS AND OF PATIENTS WITH PULMONARY ARTERIAL-HYPERTENSION
    BOGREN, HG
    KLIPSTEIN, RH
    MOHIADDIN, RH
    FIRMIN, DN
    UNDERWOOD, SR
    REES, RSO
    LONGMORE, DB
    AMERICAN HEART JOURNAL, 1989, 118 (05) : 990 - 999
  • [8] MAGNETIC-RESONANCE IMAGING OF REROUTED PULMONARY BLOOD-FLOW
    SOULEN, RL
    DONNER, RM
    CIRCULATION, 1985, 72 (04) : 29 - 29
  • [9] MAGNETIC-RESONANCE IMAGING OF REROUTED PULMONARY BLOOD-FLOW
    SOULEN, RL
    DONNER, RM
    RADIOLOGIC CLINICS OF NORTH AMERICA, 1985, 23 (04) : 737 - 744
  • [10] MEASUREMENT OF RENAL BLOOD-FLOW BY MAGNETIC-RESONANCE ANGIOGRAPHY
    LUNDIN, B
    MEYER, R
    COOPER, T
    POTCHEN, EJ
    LANCET, 1992, 339 (8789): : 373 - 373