OXYGEN-CONSUMPTION AND CARBON-DIOXIDE PRODUCTION DURING LIQUID VENTILATION

被引:24
|
作者
HIRSCHL, RB
GROVER, B
MCCRACKEN, M
WOLFSON, MR
SHAFFER, TH
BARTLETT, RH
机构
[1] ST CHRISTOPHERS HOSP CHILDREN,PHILADELPHIA,PA 19133
[2] UNIV MICHIGAN,DEPT SURG,ANN ARBOR,MI 48109
[3] TEMPLE UNIV,HLTH SCI CTR,SCH MED,DEPT PHYSIOL,PHILADELPHIA,PA 19140
[4] TEMPLE UNIV,HLTH SCI CTR,SCH MED,DEPT PEDIAT,PHILADELPHIA,PA 19140
关键词
LIQUID VENTILATION;
D O I
10.1016/0022-3468(93)90608-N
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Liquid ventilation with perfluorocarbon (PFCV) has advantages over conventional gas ventilation (GV) in premature and lung-injured newborn animals. Indirect calorimetric measurement of both oxygen consumption (V̇O2) and carbon dioxide production (V̇CO2) during PFCV has not been previously performed. In addition, comparison to indirect calorimetric measurement of V̇O2 and V̇CO2 during GV has not been evaluated. Ten fasted normal cats weighing 2.6 to 3.9 kg were anesthetized with pentobarbital and pancuronium. Tracheostomy was performed. Gas exchange was measured across the native lung during GV and across the membrane lung of the liquid ventilator during PFCV. V̇O2 was measured using a modification of a previously described, indirect, closed-circuit, volumetric technique. V̇CO2 was analyzed by capnographic assay of the mixed-expired closed-circuit air. The V̇CO2/V̇O2 ratio (RQ) was calculated. There was no change in V̇O2, V̇CO2, or RQ during PFCV when compared with GV (V̇O2: GV = 5.7 ± 0.3 mL/kg/min, PFCV = 5.6 ± 0.5 mL/kg/min [P = NS]; V̇CO2 : GV = 4.9 ± 1.1 mL/kg/min, PFCV = 4.8 ± 0.9 mL/kg/min [P = NS]; RQ: GV = 0.85 ± 0.21, PFCV = 0.86 ± 0.21 [P = NS]). During GV the PaO2 was higher than during PFCV (PaO2: GV = 335 ± 70 mm Hg, PFCV = 267 ± 83 mm Hg [P = .04]), as is expected because of the relative reduction in the inspiratory PiO2 of the perfluorocarbon during liquid ventilation. There was no significant change in the PaCO2 (PaCO2: GV = 37.3 ± 2.2 mm Hg, PFCV = 40.4 ± 5.3 mm Hg [P = NS] or the pH (pH: GV = 7.34 ± 0.04, PFCV = 7.35 ± 0.06 [P = NS]). This study demonstrates the efficacy of measuring V̇O2 and V̇CO2 during gas and liquid ventilation using an indirect calorimetric technique. The data demonstrate that V̇O2 and V̇CO2 do not change during liquid ventilation and that excellent gas exchange can be accomplished through PFCV. © 1993.
引用
收藏
页码:513 / 519
页数:7
相关论文
共 50 条
  • [1] CALCULATION OF OXYGEN-CONSUMPTION AND CARBON-DIOXIDE PRODUCTION DURING ANESTHESIA
    GRONERT, GA
    ANESTHESIA AND ANALGESIA, 1994, 79 (05): : 1018 - 1019
  • [2] RELATIONSHIP BETWEEN MINUTE VENTILATION OXYGEN-CONSUMPTION AND CARBON-DIOXIDE PRODUCTION IN THE NEWBORN
    SCHULZE, K
    KAIRAM, R
    INDYK, L
    WUNG, J
    SCIACCA, R
    DELL, R
    JAMES, LS
    PEDIATRIC RESEARCH, 1979, 13 (04) : 540 - 540
  • [3] CALCULATION OF OXYGEN-CONSUMPTION AND CARBON-DIOXIDE PRODUCTION DURING ANESTHESIA - RESPONSE
    KARAN, SM
    ANESTHESIA AND ANALGESIA, 1994, 79 (05): : 1019 - 1019
  • [4] AN IN-VITRO EVALUATION OF AN INSTRUMENT DESIGNED TO MEASURE OXYGEN-CONSUMPTION AND CARBON-DIOXIDE PRODUCTION DURING MECHANICAL VENTILATION
    WEISSMAN, C
    SARDAR, A
    KEMPER, M
    CRITICAL CARE MEDICINE, 1994, 22 (12) : 1995 - 2000
  • [5] CONTINUOUS MEASUREMENT OF OXYGEN-CONSUMPTION AND CARBON-DIOXIDE PRODUCTION IN MAN
    HUGHES, SW
    LANIGAN, C
    MOXHAM, J
    PONTE, J
    JOURNAL OF PHYSIOLOGY-LONDON, 1986, 371 : P233 - P233
  • [6] CHANGE IN OXYGEN-CONSUMPTION AND CARBON-DIOXIDE PRODUCTION AS A PREDICTOR FOR SUCCESSFUL EXTUBATION
    KEMPER, MS
    WEISSMAN, C
    ASKANAZI, J
    HYMAN, AI
    KINNEY, JM
    CRITICAL CARE MEDICINE, 1986, 14 (04) : 373 - 373
  • [7] NONINVASIVE, CONTINUOUS MONITORING DURING ASSISTED VENTILATION IN NEWBORNS BY PERMANENT MEASUREMENT OF MINUTE VOLUME, OXYGEN-CONSUMPTION AND CARBON-DIOXIDE PRODUCTION
    LEIDIG, E
    NOLLER, F
    MENTZEL, H
    KLINISCHE PADIATRIE, 1986, 198 (04): : 321 - 325
  • [8] SIMPLE PROCEDURE FOR SIMULTANEOUS DETERMINATION OF OXYGEN-CONSUMPTION AND PRODUCTION OF LABELED CARBON-DIOXIDE
    GARBUS, J
    MILLER, RM
    CAPONITE, MJ
    MYERS, CS
    ANALYTICAL BIOCHEMISTRY, 1975, 67 (02) : 669 - 671
  • [9] DOPAMINE INFUSION INCREASES CARBON-DIOXIDE PRODUCTION AND OXYGEN-CONSUMPTION IN NORMAL VOLUNTEERS
    ANDERSON, HL
    FAZZALARI, FL
    ARNOLDI, DK
    DECHERT, RE
    BARTLETT, RH
    FASEB JOURNAL, 1993, 7 (03): : A229 - A229
  • [10] OXYGEN-CONSUMPTION AND CARBON-DIOXIDE PRODUCTION FOLLOWING OPEN-HEART SURGERY
    NISHIMURA, N
    YUKI, T
    RESUSCITATION, 1985, 13 (01) : 15 - 23