BEHAVIOR OF AC HIGH VOLTAGE POLYAMIDE INSULATORS: EVOLUTION OF LEAKAGE CURRENT IN DIFFERENT SURFACE CONDITIONS

被引:12
|
作者
Slama, Mohammed El Amine [1 ]
Beroual, Abderrahmane [1 ]
机构
[1] Univ Lyon, CNRS, Ecole Cent Lyon, AMPERE UMR 5005, 36 Ave Guy Collongue, F-69134 Ecully, France
关键词
Dielectric; electrical arc; flashover; humidity; insulator; leakage current; partial discharges; pollution; polyamide;
D O I
10.15598/aeee.v13i2.1145
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper is aimed at a systematic study of the leakage current of high voltage polyamide insulator string under different conditions of pollution for possible application in the electric locomotive systems. It is shown that in the case of clean/dry and clean/wetted insulators, the leakage current and applied voltage are linear. While in the case of pollution with saline spray, the leakage current and the applied voltage are not linear; the leakage current changes from a linear regime to a nonlinear regime up to total flashover of the insulators sting. Traces of erosion and tracking of insulators resulting of partial discharges are observed.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [1] Experimental Study of the Flashover Process and the Leakage Current on the Surface of High Voltage Insulator Under AC Voltage
    Benguesmia, Hani
    Bakri, Badis
    Mekkas, Yasmine
    M'ziou, Nassima
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2024, : 2553 - 2567
  • [2] Factors affecting the leakage current bursts of high voltage polluted insulators
    Gouda, OE
    Amer, GM
    UPEC 2004: 39th International Universitities Power Engineering Conference, Vols 1-3, Conference Proceedings, 2005, : 114 - 117
  • [3] Predictive dynamic model of the leakage current and flashover voltage of discontinuously polluted insulators under ac voltage: experimental validation
    Dhahbi-Megriche, N.
    Beroual, A.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2007, 40 (24) : 7782 - 7786
  • [4] Frequency characters of leakage current on the surface of outdoor insulators in different relative humidity
    Mao Yingke
    Guan Zhicheng
    Wang Liming
    Wang xin
    Yue Bo
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 692 - 695
  • [5] Statistical analysis of leakage current fluctuations on 20 kV high voltage porcelain insulators
    Tsarabaris, P. T.
    Halaris, P. G.
    Polykrati, A. D.
    Paraskevopoulos, A. A. P.
    Dimitriadou, D. D.
    Theodorou, N. J.
    PROCEEDINGS OF THE SIXTH IASTED INTERNATIONAL CONFERENCE ON EUROPEAN POWER AND ENERGY SYSTEMS, 2006, : 105 - +
  • [6] The Leakage Current Components as a Diagnostic Tool to Estimate Contamination Level on High Voltage Insulators
    Salem, Ali A.
    Abd-Rahman, R.
    Al-Gailani, Samir Ahmed
    Kamarudin, M. S.
    Ahmad, Hussein
    Salam, Zainal
    IEEE ACCESS, 2020, 8 : 92514 - 92528
  • [7] Characterization of Leakage Current on High Voltage Glass Insulators Using Wavelet Transform Technique
    Algeelani, Nasir Ahmed
    Piah, M. Afendi M.
    2012 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS), VOLS 1-2, 2012, : 882 - 885
  • [8] Leakage Current Prediction for High Voltage Insulators Flashover based on Extreme Value Theory
    Ali, Hui
    2016 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C), 2016, : 870 - 873
  • [9] Effect of Different Factors on the Leakage Current Behavior of Silicon Photovoltaic Modules at High Voltage Stress
    Islam, Mohammad Aminul
    Hasanuzzaman, M.
    Abd Rahim, Nasrudin
    IEEE JOURNAL OF PHOTOVOLTAICS, 2018, 8 (05): : 1259 - 1265
  • [10] Performance Evaluation of Insulators Using Flashover Voltage and Leakage Current
    Samimi, Mohammad Hamed
    Mostajabi, Amir Hossein
    Ahmadi-Joneidi, Iman
    Shayegani-Akmal, Amir Abbas
    Mohseni, Hossein
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (02) : 221 - 233