LOW-LEVEL ELECTROCHEMICAL DETECTION OF GLUCOSE-OXIDASE AND A GLUCOSE-OXIDASE CONJUGATE

被引:1
|
作者
ALLEN, RM [1 ]
BENNETTO, HP [1 ]
LEWIS, IAS [1 ]
MASON, JR [1 ]
WESTRA, AR [1 ]
机构
[1] UNIV LONDON KINGS COLL,DEPT CHEM,LONDON W8 7AH,ENGLAND
来源
BIOSENSORS & BIOELECTRONICS | 1995年 / 10卷 / 6-7期
关键词
GLUCOSE OXIDASE; PLATINIZED CARBON PAPER ELECTRODE; AMPEROMETRY; HYDROGEN PEROXIDE; GLUCOSE OXIDASE CONJUGATE; ENZYME LABEL;
D O I
10.1016/0956-5663(95)96938-U
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An amperometric sensor for glucose oxidase is described. Partial optimization of the working electrode potential at 0.4 V vs. Ag/AgCl, 0.1 M KCl at a glucose concentration of 30 mM allows a low detection limit of 50 pM glucose oxidase within 25 min. The sensor exhibits a high degree of precision and reproducibility, and the same electrode may be re-used for many successive quantitative determinations. A mechanism for the sensor is proposed, in which hydrogen peroxide generated by glucose oxidase in bulk solution is oxidized at the working electrode, generating a current response that can be related to the glucose oxidase concentration. Conjugation of glucose oxidase with a coumarin-based pesticide analogue does not affect the amperometric response.
引用
收藏
页码:621 / 631
页数:11
相关论文
共 50 条
  • [1] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 184 (SEP): : 47 - MICR
  • [2] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1984, 9 (01) : 95 - 104
  • [3] DETECTION OF GLUCOSE BY USING IMMOBILIZED GLUCOSE-OXIDASE
    MANOCHIOPINIJ, S
    SAPSAMARNWONG, C
    SIRISALI, K
    JOURNAL OF THE SCIENCE SOCIETY OF THAILAND, 1985, 11 (02): : 79 - 91
  • [4] AN INTERFERING FACTOR IN THE GLUCOSE-OXIDASE SENSING SYSTEM WITH POLYPYRROLE GLUCOSE-OXIDASE MEMBRANE
    KOJIMA, K
    NASU, H
    SHIMOMURA, M
    MIYAUCHI, S
    SYNTHETIC METALS, 1995, 71 (1-3) : 2245 - 2246
  • [5] OXIDATION OF GLUCOSE ON IMMOBILIZED GLUCOSE-OXIDASE
    TSUKAMOTO, T
    MORITA, S
    OKADA, J
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1982, 30 (03) : 782 - 788
  • [6] GLUCOSE-OXIDASE - AN IDEAL ENZYME
    WILSON, R
    TURNER, APF
    BIOSENSORS & BIOELECTRONICS, 1992, 7 (03): : 165 - 185
  • [7] A METHOD FOR IMMOBILISING GLUCOSE-OXIDASE
    SAHAI, V
    DAS, K
    INDIAN JOURNAL OF BIOCHEMISTRY & BIOPHYSICS, 1980, 17 (04): : 287 - 289
  • [8] GLUCOSE-OXIDASE IMMUNOENZYME TECHNIQUE
    LEWIN, KJ
    SUFFIN, SC
    PORTER, DD
    MUCK, KB
    YOUNG, JC
    LABORATORY INVESTIGATION, 1979, 40 (02) : 269 - 269
  • [9] GLUCOSE-OXIDASE AS A PHARMACEUTICAL ANTIOXIDANT
    BERG, TF
    NIEBERGALL, PJ
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1992, 18 (16) : 1813 - 1822
  • [10] MODIFICATION OF GLUCOSE-OXIDASE BY TETRATHIAFULVALENE
    BARTLETT, PN
    BRADFORD, VQ
    JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1990, (16) : 1135 - 1136