EXPERIMENTAL-VERIFICATION OF EFFECTIVENESS AND HARMLESSNESS OF THE QIGONG MANEUVER

被引:0
|
作者
ZHANG, SX [1 ]
GUO, HZ [1 ]
JING, BS [1 ]
WANG, X [1 ]
ZHANG, LM [1 ]
机构
[1] PEOPLES LIBERAT ARMY,AIR FORCE,INST AVIAT MED,DEPT AIRCREW HLTH MAINTENANCE,BEIJING 100036,PEOPLES R CHINA
来源
关键词
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A series of experiments involving the Qigong (Q-G) maneuver were conducted after our preliminary studies in 1986. Eighteen active fighter pilots served as subjects. After mastery of the Q-G maneuver in 5-7 sessions of training, tests at +1 Gz further verified that the blood pressure raising effect of this maneuver has the characteristics of rapid rising, minimal fluctuation and being readily maintained. The 18 subjects then underwent centrifuge tests. The tolerance to Rapid Onset Rate (ROR) (1 G/s) G-load in a relaxed, unprotected condition was 3.82 G on average; performing the Q-G maneuver, the tolerance rose to 6.64 G, an improvement of 2.82 G. One to two days later, 5 subjects with anti-G suits on and performing the Q-G maneuver tolerated 7.80 G on average (ROR 1 G/s), a gain of 3.95 G. Another 9 subjects performing the Q-G maneuver endured high sustained G (HSG) (ROR 3 G/s) of 6.5 G for 74.4 s on average (max 96 s) and 3 subjects endured HSG of 7.0 G for 57 s on average (max 82 s). During centrifuge tests, recorded physiological values showed good tolerance of the subjects; the respiratory pattern was basically different from that of M-1 or L-1 maneuvers. In further testing the harmlessness of the Q-G maneuver, gas metabolism, ear lobe oximetry and 8-channel EEG were carried out on these subjects. All these indices plus close monitoring during centrifuge tests proved that the Q-G maneuver does not lead to hypoxia or hyperventilation. It has been shown that the Q-G maneuver is an innovative G-protective maneuver that is remarkably effective, theoretically interesting, reliable, and practical. Its mechanism warrants investigation.
引用
收藏
页码:46 / 52
页数:7
相关论文
共 50 条
  • [1] THE SLOT IMPEDANCE - EXPERIMENTAL-VERIFICATION
    HOOLE, SRH
    WALSH, TH
    STEVENS, GH
    IEEE TRANSACTIONS ON MAGNETICS, 1988, 24 (06) : 3156 - 3158
  • [2] EXPERIMENTAL-VERIFICATION OF ULTRASONIC TRANSMISSIVITY
    ERMOLOV, IN
    KIYATKIN, DV
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 1993, 29 (05) : 317 - 320
  • [3] EXPERIMENTAL-VERIFICATION OF AURICULODIAGNOSIS IN THE DOG
    STILL, J
    KONRAD, J
    ACTA VETERINARIA BRNO, 1985, 54 (3-4) : 169 - 175
  • [4] EXPERIMENTAL-VERIFICATION OF THE SPINODAL CURVE
    ABRAHAM, FF
    MRUZIK, MR
    POUND, GM
    JOURNAL OF CHEMICAL PHYSICS, 1979, 70 (05): : 2577 - 2579
  • [5] A POSSIBLE EXPERIMENTAL-VERIFICATION OF RETROACTIVITY
    RIETDIJK, CW
    PHYSICA B & C, 1988, 151 (1-2): : 358 - 361
  • [6] EXPERIMENTAL-VERIFICATION OF SPECIAL RELATIVITY
    COOPER, PS
    ALGUARD, MJ
    BAUM, G
    COWARD, DH
    EHRLICH, RD
    HUGHES, VW
    KOBAYAKAWA, H
    KONDO, K
    LADISH, JS
    LUBELL, MS
    MILLER, RH
    PRESCOTT, CY
    RAITH, W
    SASAO, N
    SCHULER, KP
    SHERDEN, DJ
    SINCLAIR, CK
    SOUDER, PA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (01): : 72 - 72
  • [7] EXPERIMENTAL-VERIFICATION OF A VECTOR PREISACH MODEL
    VAJDA, F
    OTI, J
    PARDAVIHORVATH, M
    DELLATORRE, E
    SWARTZENDRUBER, LJ
    BENNETT, LH
    JOURNAL OF APPLIED PHYSICS, 1991, 69 (08) : 4502 - 4504
  • [8] EXPERIMENTAL-VERIFICATION OF THE MACCORMACK NUMERICAL SCHEME
    JOVANOVIC, M
    DJORDJEVIC, D
    ADVANCES IN ENGINEERING SOFTWARE, 1995, 23 (01) : 61 - 67
  • [9] EXPERIMENTAL-VERIFICATION OF A MULTIVARIABLE CONTROLLED AUXOSTAT
    GOSTOMSKI, PA
    CLESCERI, LS
    BUNGAY, HR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 202 : 158 - BIOT
  • [10] PRINCIPLE AND EXPERIMENTAL-VERIFICATION OF COMPENSATION CALORIMETRY
    ZHONG, GX
    MA, ST
    ZHAO, HG
    SHEN, JR
    HUANG, Y
    THERMOCHIMICA ACTA, 1988, 123 : 93 - 103