SPIRAL CT OF THE MEDIASTINUM - OPTIMIZATION OF CONTRAST-MEDIUM USE

被引:5
|
作者
STORTO, ML
CICCOTOSTO, C
PATEA, RL
SPINAZZI, A
BONOMO, L
机构
[1] Radiology Department, University of Chieti, 'SS Annunziata' Hospital, 66100 Chieti, Via P. Valignani
[2] Research and Development Division, Medical Department, Bracco SpA., I-20134 Milan
关键词
COMPUTED TOMOGRAPHY; TECHNOLOGY; MEDIASTINUM; CONTRAST MEDIA; COMPARATIVE STUDY;
D O I
10.1016/0720-048X(94)90099-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spiral computed tomography (CT) allows very satisfactory temporal resolution for the detection and analysis of changes in contrast medium density, so that volumes of contrast material smaller than those recommended for conventional CT can be used. The present double-blind, parallel group study was designed to compare image quality and diagnostic efficacy obtained with two different iodine strengths (200 and 300 mgI/ml) and two different flow rates (2 and 3 ml/s) of a fixed volume (70 ml) of iomeprol in adult consenting patients requiring spiral CT of the mediastinum. Imaging was performed during suspended respiration and, a 15-s delay to scan. Spiral CT was initiated 1 cm above the aortic arch and continued inferiorly for 24 cm in all patients. Two independent readers blindly graded image quality, opacification of the superior vena cava, thoracic aorta and pulmonary arteries, and overall diagnostic quality of the CT examination. CT density measurements were performed over the level of the aortic arch, left and right pulmonary arteries, left atrium, and descending aorta. Opacification of the mediastinal vessels was better in the patients injected at 3 ml/s flow rate and was independent of the iodine strength used, except in the case of the thoracic aorta, which was better opacified by injecting iomeprol 300 mgI/ml at 3 ml/s. The highest diagnostic efficacy of the spiral CT examination was obtained with iomeprol 300 mgI/ml at 3 ml/s infusion rate, which seems to represent the administration scheme of choice.
引用
收藏
页码:S83 / S87
页数:5
相关论文
共 50 条
  • [1] OPTIMIZATION OF CONTRAST-MEDIUM BOLUS IN SPIRAL CT
    KOPKA, L
    FUNKE, M
    KRUGER, M
    SCHRODER, T
    SCHULZ, R
    GRABBE, E
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (04): : 361 - 363
  • [2] DOSE OPTIMIZATION OF A NONIONIC INTRAVENOUS CONTRAST-MEDIUM FOR SPIRAL CT OF THE ABDOMEN
    FISHMAN, EK
    ANDERSON, JH
    BROWN, PC
    BLUEMKE, DA
    RADIOLOGY, 1992, 185 : 114 - 114
  • [3] OPTIMIZATION AND ADAPTATION OF INTRAVENOUS CONTRAST-MEDIUM DOSAGE IN CT DIAGNOSIS OF THORAX
    EHRITTBRAUN, C
    FERSTL, F
    BURGER, D
    KRAUSE, W
    LANGER, M
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (04): : 364 - 365
  • [4] THE USE OF A LOW-OSMOLALITY CONTRAST-MEDIUM IN HYSTEROSALPINGOGRAPHY - COMPARISON WITH A CONVENTIONAL CONTRAST-MEDIUM
    DAVIES, AC
    KEIGHTLEY, A
    BORTHWICKCLARKE, A
    WALTERS, HL
    CLINICAL RADIOLOGY, 1985, 36 (05) : 533 - 536
  • [5] HYPERTHYROIDISM AFTER USE OF CONTRAST-MEDIUM
    SILAS, AM
    WHITE, AG
    BRITISH MEDICAL JOURNAL, 1975, 4 (5989): : 162 - 162
  • [6] CONTRAST-MEDIUM PRECIPITATION DURING ABDOMINAL CT
    BALL, DS
    RADECKI, PD
    FRIEDMAN, AC
    CAROLINE, DF
    MAYER, DP
    RADIOLOGY, 1986, 158 (01) : 258 - 260
  • [7] SIGNIFICANCE OF INTRAVENOUS CONTRAST-MEDIUM IN CEREBRAL CT
    SOTANIEMI, KA
    PYHTINEN, J
    HOKKANEN, TE
    MYLLYLA, VV
    UPSALA JOURNAL OF MEDICAL SCIENCES, 1986, : 24 - 24
  • [8] INTESTINAL CONTRAST IMAGING IN ABDOMINAL CT - WATER OR CONTRAST-MEDIUM
    SCHUNK, K
    DUBER, C
    KREITNER, KF
    BRUNIER, A
    KLOSE, KJ
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (04): : 407 - 413
  • [9] INTESTINAL CONTRAST IMAGING IN ABDOMINAL CT - WATER OR CONTRAST-MEDIUM
    TROGER, J
    BUSSMANN, H
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 155 (04): : 382 - 382
  • [10] Optimization of thoracic spiral CT: Effects of iodinated contrast medium concentration
    Rubin, GD
    Lane, MJ
    Bloch, DA
    Leung, AN
    Stark, P
    RADIOLOGY, 1996, 201 (03) : 785 - 791