To record weak light scattering spectra with a Fabry-Perot interferometer, long measuring times are often necessary. For long term stability of the parallel alignment of the mirrors, a microcomputer controlled interferometer system has been developed for both single and multipass operation. The three piezo stacks, which are responsible for the alignment of the mirrors, are supplied from three digital-to-analog converters controlled by a personal computer. The test and correction steps of the mirror alignment are performed around two independent axes perpendicular to each other. A special function generator provides a nonlinear scanning ramp for the piezostacks, thereby allowing a temporally linear scanning of the Fabry-Perot. © 1990 Optical Society of America.
引用
收藏
页码:953 / 958
页数:6
相关论文
共 50 条
  • [1] SERVO-CONTROLLED FABRY-PEROT-INTERFEROMETER WITH ONLINE COMPUTER CONTROL
    HICKS, TR
    REAY, NK
    STEPHENS, CL
    ASTRONOMY & ASTROPHYSICS, 1976, 51 (03) : 367 - 374
  • [2] MULTIPLEX FABRY-PEROT-INTERFEROMETER
    HAYS, PB
    SNELL, HE
    APPLIED OPTICS, 1991, 30 (22): : 3108 - 3113
  • [3] SERVOCONTROL OF A FABRY-PEROT-INTERFEROMETER
    WINTER, JG
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (06): : 505 - 509
  • [4] BICONFOCAL FABRY-PEROT-INTERFEROMETER
    MAZURENKO, YT
    OPTIKA I SPEKTROSKOPIYA, 1990, 69 (02): : 241 - 243
  • [5] FABRY-PEROT-INTERFEROMETER FOR ATOMS
    WILKENS, M
    GOLDSTEIN, E
    TAYLOR, B
    MEYSTRE, P
    PHYSICAL REVIEW A, 1993, 47 (03): : 2366 - 2369
  • [6] SCANNING FABRY-PEROT-INTERFEROMETER
    CHANIN, G
    LECULLIER, JC
    INFRARED PHYSICS, 1978, 18 (5-6): : 589 - 594
  • [7] ON MULTIPASS FABRY-PEROT-INTERFEROMETER
    COPIC, M
    ZGONIK, M
    OPTICS COMMUNICATIONS, 1982, 41 (05) : 310 - 314
  • [8] COMPUTER-CONTROLLED FABRY-PEROT-INTERFEROMETER FOR BRILLOUIN SPECTROSCOPY
    ASENBAUM, A
    APPLIED OPTICS, 1979, 18 (04): : 540 - 544
  • [9] APPLICATION OF THE FABRY-PEROT-INTERFEROMETER AS A REFRACTOMETER
    KHASHAN, MA
    OPTICA ACTA, 1979, 26 (07): : 881 - 888
  • [10] CHAOS IN A FEEDBACK FABRY-PEROT-INTERFEROMETER
    TAKIZAWA, T
    LIU, Y
    OHTSUBO, J
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1994, 30 (02) : 334 - 338