INITIAL EVALUATION OF A NEW INTRAARTERIAL BLOOD-GAS SYSTEM IN HUMANS

被引:65
|
作者
ZIMMERMAN, JL [1 ]
DELLINGER, RP [1 ]
机构
[1] BAYLOR COLL MED,HOUSTON,TX 77030
关键词
BLOOD GAS ANALYSIS; MONITORING; FIBEROPTIC SENSORS; EQUIPMENT; OXYGENATION; VENTILATION; PHYSIOLOGICAL; HEMODYNAMICS; CRITICAL CARE; ACID-BASE EQUILIBRIUM; PULMONARY EMERGENCIES;
D O I
10.1097/00003246-199304000-00006
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the in vivo performance of a continuous intra-arterial blood gas monitor as compared with in vitro arterial blood gases for measurements of Pao2, Paco2, and arterial pH. Design: Consecutive patient enrollment. Setting: Medical intensive care unit of a county teaching hospital. Patients. Five critically ill patients. Interventions. All patients had a fiberoptic sensor placed through a 20-gauge cannula inserted into the radial artery. Sensor and arterial blood gas measurements were monitored up to 68 hrs. Arterial blood gases were analyzed on two blood gas analyzers. Measurements and Main Results. A total of 104 arterial blood gases were obtained for comparison of sensor measurements with blood gas analyzer values. Comparison of the sensor values with the blood gas analyzer values showed bias and precision values of -0.021 and 0.037 for arterial pH, 1.74 and 6.06 torr (0.23 and 0.81 kPa) for Paco2, and -5.89 and 13.19 torr (-0.79 and 1.76 kPa) for Pao 2, respectively. Comparison of the two blood gas analyzer measurements showed bias and precision values of -0.030 and 0.010 for arterial pH, 1.96 and 2.55 torr (0.26 and 0.34 kPa) for Paco2, and -5.77 and 17.15 torr (-0.77 and 2.29 kPa) for Pao2, respectively. No complications attributable to the sensor were detected. Conclusions: The performance of this fiberoptic continuous intra-arterial blood gas monitor is comparable to that of blood gas analyzers and compares favorably with previously reported studies utilizing other sensors in reliably and reproducibly approximating Pao2, Paco2, and arterial pH values. This monitoring capability was accomplished with no patient morbidity. Further study is indicated to confirm these initial results and to establish the role of a continuous intra-arterial blood gas monitor in critically ill patients.
引用
收藏
页码:495 / 500
页数:6
相关论文
共 50 条
  • [1] EVALUATION OF A NEW INTRAARTERIAL BLOOD-GAS SYSTEM IN DOGS
    SHAPIRO, BA
    CANE, RD
    CHOMKA, CM
    GEHRICH, JL
    TUSA, JK
    CRITICAL CARE MEDICINE, 1987, 15 (04) : 361 - 361
  • [2] MULTISITE EVALUATION OF A CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM
    LARSON, CP
    VENDER, J
    SEIVER, A
    ANESTHESIOLOGY, 1994, 81 (03) : 543 - 552
  • [3] PRELIMINARY EVALUATION OF A NEW CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING DEVICE
    PAPPERT, D
    ROSSAINT, R
    LEWANDOWSKI, K
    KUHLEN, R
    GERLACH, H
    FALKE, KJ
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 : 67 - 70
  • [4] A NEW TECHNOLOGY FOR CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORS
    NEARMAN, HS
    HERMAN, ML
    CLAY, W
    HUTTON, M
    ANESTHESIOLOGY, 1993, 79 (3A) : A565 - A565
  • [5] EVALUATION OF AN INTRAARTERIAL BLOOD-GAS MONITOR IN MECHANICALLY VENTILATED PATIENTS
    BARRERA, R
    LOIACONO, J
    GROEGER, JS
    CARLON, GC
    ANESTHESIOLOGY, 1994, 81 (3A) : A615 - A615
  • [6] EVALUATION OF A CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITOR IN CARDIOTHORACIC SURGERY
    SHENAQ, SA
    ZIMMERMAN, JL
    CURLING, PE
    ANESTHESIOLOGY, 1994, 81 (3A) : A616 - A616
  • [7] CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING
    MAHUTTE, CK
    INTENSIVE CARE MEDICINE, 1994, 20 (02) : 85 - 86
  • [8] INTRAARTERIAL BLOOD-GAS MONITORING - COMPARISON WITH IN-VITRO BLOOD-GAS MEASUREMENTS
    PATEL, C
    ALEXANDER, L
    DOWSEY, K
    KAUFMAN, L
    BHATT, S
    ANESTHESIOLOGY, 1994, 81 (3A) : A155 - A155
  • [9] A MULTIPARAMETER SENSOR FOR CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING - A PROSPECTIVE EVALUATION
    VENKATESH, B
    BROCK, THC
    HENDRY, SP
    CRITICAL CARE MEDICINE, 1994, 22 (04) : 588 - 594
  • [10] CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING - REPLY
    VENKATESH, B
    CLUTTONBROCK, TH
    HENDRY, SP
    CRITICAL CARE MEDICINE, 1995, 23 (04) : 788 - 789