VISUALIZATION OF BRAIN-STEM PERFUSION USING A HIGH SPATIAL-RESOLUTION SPECT SYSTEM

被引:3
|
作者
DIERCKX, R
DOBBELEIR, A
VANDEVIVERE, J
ABTS, H
DEDEYN, PP
机构
[1] MIDDELHEIM HOSP,DEPT NUCL MED,ANTWERP,BELGIUM
[2] MIDDELHEIM HOSP,DEPT NEUROL,ANTWERP,BELGIUM
[3] UNIV INSTELLING ANTWERP,BORN BUNGE FDN,NEUROCHEM LAB,B-2610 WILRIJK,BELGIUM
关键词
D O I
10.1097/00003072-199205000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors explored the high spatial resolution of a three-head rotating SPECT system, equipped with lead super-fine fanbeam collimator. The brainstem was high-lighted in a three-dimensional reconstruction, showing perfusion small structures such as mesencephalon, pons, and medulla oblongata. The visualization of brainstem perfusion sets new landmarks in functional neuroimaging and, moreover, was obtained with a commercially available three-head SPECT system.
引用
收藏
页码:378 / 379
页数:2
相关论文
共 50 条
  • [1] Conceptual Design of High Spatial-Resolution SPECT System for Human Brain
    Zeniya, Tsutomu
    Hirano, Yoshiyuki
    Tominaga, Takanori
    Hori, Yuki
    Watabe, Hiroshi
    Sakimoto, Tomonori
    Sohlberg, Antti
    Minato, Kotaro
    Hatazawa, Jun
    Iida, Hidehiro
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3426 - 3428
  • [2] SPATIAL-RESOLUTION AND COUNT DENSITY REQUIREMENTS IN BRAIN SPECT IMAGING
    MADSEN, MT
    CHANG, W
    HICHWA, RD
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (08): : 1625 - 1636
  • [3] AUGER MICROSCOPY WITH HIGH SPATIAL-RESOLUTION IN A STEM
    CHAZELAS, J
    OLIVIER, J
    CHARASSE, MN
    CABANEL, R
    HIRTZ, JP
    MAGIS, M
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1988, 13 (05): : 371 - 377
  • [4] SCATTER, SPATIAL-RESOLUTION, AND QUANTITATIVE RECOVERY IN HIGH-RESOLUTION SPECT
    SZABO, Z
    LINKS, JM
    SEKI, C
    RHINE, J
    WAGNER, HN
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (03) : 461 - 467
  • [5] HIGH SPATIAL-RESOLUTION SPECT OF THE HEAD USING ROTATING GAMMA-CAMERA
    LARSSON, SA
    BERGSTRAND, G
    BERGSTEDT, H
    BERG, J
    FLYGARE, O
    SCHNELL, PO
    ANDERSSON, N
    LAGERGREN, C
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1984, 9 (07): : A11 - A11
  • [6] BRAIN-STEM INFARCTION AND DIASCHISIS - A SPECT CEREBRAL PERFUSION STUDY
    FAZEKAS, F
    PAYER, F
    VALETITSCH, H
    SCHMIDT, R
    FLOOH, E
    STROKE, 1993, 24 (08) : 1162 - 1166
  • [7] HIGH SPATIAL-RESOLUTION SECONDARY AND AUGER IMAGING IN A STEM
    DRUCKER, JS
    KRISHNAMURTHY, M
    HONG, LC
    HEMBREE, GG
    VENABLES, JA
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1990, (98): : 303 - 306
  • [8] HIGH SPATIAL-RESOLUTION MICROANALYSIS OF ELECTRONIC MATERIALS USING EDS AND EELS IN THE STEM
    LONG, NJ
    GLAISHER, RW
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1990, (98): : 277 - 280
  • [9] HIGH SPATIAL-RESOLUTION MICROANALYSIS OF ELECTRONIC MATERIALS USING EELS AND EDS IN THE STEM
    LONG, NJ
    MICROSCOPY OF SEMICONDUCTING MATERIALS 1989, 1989, 100 : 59 - 67
  • [10] EFFECT OF SPATIAL-RESOLUTION ON SPECT QUANTIFICATION VALUES
    KOJIMA, A
    MATSUMOTO, M
    TAKAHASHI, M
    HIROTA, Y
    YOSHIDA, H
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (04) : 508 - 514