A PORTABLE SYSTEM FOR THE CONTINUOUS MEASUREMENT OF RN-222 IN HOSTILE GEOPHYSICAL ENVIRONMENTS

被引:7
|
作者
CHAMBAUDET, A [1 ]
CIEUR, M [1 ]
HUSSONOIS, M [1 ]
KLEIN, D [1 ]
机构
[1] INST PHYS NUCL,F-91406 ORSAY,FRANCE
关键词
D O I
10.1016/0168-583X(91)95470-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A proportional counter has been developed for the continuous measurement of Rn-222 in particularly hostile environmental conditions. This portable instrument has a one month autonomy and the detection sensitivity allows activity exceeding 41 Bq/m3 to be measured. The system is also adapted for volcanology and seismology observations, since Rn-222 is considered as a possible earthquake prediction signal. This apparatus has been tested regarding its ability to measure variations in radon concentration which are used as a tracer for understanding the geophysical processes that induce gases in the ground.
引用
收藏
页码:244 / 250
页数:7
相关论文
共 50 条
  • [1] STUDY OF RN-222 PERMEATION THROUGH POLYMER MEMBRANES - APPLICATION TO CONTINUOUS MEASUREMENT OF RN-222 IN WATER
    LABED, V
    RANNOU, A
    TYMEN, G
    HEALTH PHYSICS, 1992, 63 (02): : 172 - 178
  • [2] THE NIST PRIMARY RN-222 MEASUREMENT SYSTEM
    COLLE, R
    HUTCHINSON, JMR
    UNTERWEGER, MP
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1990, 95 (02) : 155 - 165
  • [3] CONTINUOUS RN-222 MONITOR
    SKRABLE, KW
    PHOENIX, KA
    CHABOT, GE
    FRENCH, CS
    ALEXANDER, EL
    CASPARIUS, RE
    HEALTH PHYSICS, 1986, 50 : S61 - S61
  • [4] MEASUREMENT OF RN-222 IN WATER
    COUNTESS, RJ
    HEALTH PHYSICS, 1978, 34 (04): : 390 - 391
  • [5] The Rn-222 reference measurement system developed at ENEA
    DeFelice, P
    Myteberi, X
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (2-3): : 445 - 451
  • [6] A CHARCOAL COIL MEASUREMENT SYSTEM FOR ENVIRONMENTAL RN-222
    SOLOMON, SB
    GAN, TH
    HEALTH PHYSICS, 1989, 57 (05): : 801 - 807
  • [7] MEASUREMENT OF RN-222 IN JORDANIAN DWELLINGS
    ALKOFAHI, MM
    KHADER, BR
    LEHLOOH, AD
    KULLAB, MK
    ABUMURAD, KM
    ALBATAINA, BA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (02): : 377 - 382
  • [8] METHOD OF ELIMINATING THE EFFECT OF DECAY PRODUCTS IN CONTINUOUS MEASUREMENT OF RN-222
    JANKA, K
    LEHTIMAKI, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1982, 53 (04): : 523 - 527
  • [9] CONTINUOUS MEASUREMENT OF RN-222 FLUX, CONCENTRATION AND WORKING-LEVEL
    MOMENI, MH
    MARIANDA, J
    KISIELESKI, W
    KRETZ, N
    HEALTH PHYSICS, 1979, 37 (06): : 803 - 803
  • [10] THE MEASUREMENT SYSTEM FOR RN-222 MONITORING WITH CHARCOAL ADSORPTION COLLECTORS
    DELUCA, A
    MANCINI, C
    HEALTH PHYSICS, 1991, 61 (04): : 543 - 546