Study on the Ophthalmic Lens Materials with High Refractive Index Containing Vinylanisole

被引:8
|
作者
Kim, Tae-Hun [1 ]
Sung, A-Young [1 ]
机构
[1] Daebul Univ, Dept Ophthalm Opt, Jeonnam 526702, South Korea
关键词
3-Vinylanisole; 4-Vinylanisole; Refractive index; Optical transmissibility;
D O I
10.5012/jkcs.2010.54.6.755
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study used 3-vinylanisole and 4-vinylanisole with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), NVP (N-vinyl-2-pyrrolidone) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Measurement of the physical characteristics of the copolymerized material showed that the refractive index is 1.4496 -1.4894, water content 22.93 -35.50%, visible transmittance 88.8 -90.8%. Also, measurements showed that the refractive index increased while the water content decreased as the ratio of 3-vinylanisole and 4-vinylanisole increased. And in cases of copolymer with 3-vinylanisole, 4-vinylanisole (added 15%) the results showed transmittance of 52.8 -82.2%, 13.2 - 26.2% respectively for UV-A and UV-B showing that they have UV-blocking effects. Based on the results of this study, the produced copolymer can be estimated to be suitable for use as ophthalmic lens material for high refractive index and UV-blocking effects.
引用
收藏
页码:755 / 760
页数:6
相关论文
共 50 条
  • [1] THEORETICAL COMPUTATION OF THE REFRACTIVE-INDEX IN AN OPHTHALMIC LENS
    SIMONET, P
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1987, 64 (05): : 370 - 372
  • [2] PRACTICAL LIMITATIONS IN THE COMPUTATION OF THE REFRACTIVE-INDEX OF AN OPHTHALMIC LENS - REPLY
    SIMONET, P
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1988, 65 (08): : 675 - 680
  • [3] Refractive correction measurement in an ophthalmic lens
    Trujillo-Schiaffino, G
    Malacara-Hernández, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (09): : 3622 - 3625
  • [4] Novel copolymer compositions with high refractive index and low modulus as lens substitute materials
    Ravi, N
    Aliyar, H
    Hamilton, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U707 - U707
  • [5] Study on the Physical Properties of Hydrophobic Ophthalmic Lens Materials Containing Vinyl pyridine and EOEMA
    Kim, Tae-Hun
    Sung, A-Young
    JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE, 2011, 55 (03): : 550 - 555
  • [6] A STUDY OF PROCESSED ELECTRONIC MATERIALS CONTAINING INHOMOGENEOUS REFRACTIVE-INDEX PROFILES
    AIZENBERG, GE
    SWART, PL
    LACQUET, BM
    JOURNAL OF ELECTRONIC MATERIALS, 1993, 22 (01) : 143 - 149
  • [7] High delta in gradient refractive index (GRIN) lens
    Yin, Kezhen
    Baer, Eric
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [8] High Refractive Index GRIN Lens for IR Optics
    Kang, Yan
    Wang, Jin
    Zhao, Yongkun
    Zhao, Xudong
    Tao, Haizheng
    Xu, Yinsheng
    MATERIALS, 2023, 16 (07)
  • [9] Fabrication of Microstructures Containing High Refractive Index Materials by Two-Photon Lithography
    Prabhakaran, Prem
    Jang, Kyung-Kook
    Son, Yong
    Yang, Dong-Yol
    Lee, Kwang-Sup
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2013, 578 (01) : 4 - 18
  • [10] Light path management in devices containing halide perovskite materials with a high refractive index
    Jeong, Jaemin
    Kim, Bumsoo
    Seol, Myeong Jin
    Kim, Soo Young
    MATERIALS RESEARCH BULLETIN, 2024, 175