INDOOR AIR BACTERIAL LOAD AND ANTIBIOTIC SUSCEPTIBILITY PATTERN OF ISOLATES IN OPERATING ROOMS AND SURGICAL WARDS AT JIMMA UNIVERSITY SPECIALIZED HOSPITAL, SOUTHWEST ETHIOPIA

被引:0
|
作者
Genet, Chalachew [1 ]
Kibru, Gebre [2 ]
Tsegaye, Wondewosen [2 ]
机构
[1] Samara Univ, Sch Hlth Sci, Samara, Russia
[2] Jimma Univ, Dept Med Lab Sci & Pathol, Jimma, Ethiopia
关键词
Indoor air; hospital environment; surgical site infection; Southwest Ethiopia;
D O I
暂无
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Surgical site infection is the second most common health care associated infection. One of the risk factors for such infection is bacterial contamination of operating rooms' and surgical wards' indoor air. In view of that, the microbiological quality of air can be considered as a mirror of the hygienic condition of these rooms. Thus, the objective of this study was to determine the bacterial load and antibiotic susceptibility pattern of isolates in operating rooms' and surgical wards' indoor air of Jimma University Specialized Hospital. METHODS: A cross sectional study was conducted to measure indoor air microbial quality of operating rooms and surgical wards from October to January 2009/2010 on 108 indoor air samples collected in twelve rounds using purposive sampling technique by Settle Plate Method (Passive Air Sampling following 1/1/1 Schedule). Sample processing and antimicrobial susceptibility testing were done following standard bacteriological techniques. The data was analyzed using SPSS version 16 and interpreted according to scientifically determined baseline values initially suggested by Fisher. RESULTS: The mean aerobic colony counts obtained in OR-1(46cfu/hr) and OR-2(28cfu/hr) was far beyond the set 5-8cfu/hr acceptable standards for passive room. Similarly the highest mean aerobic colony counts of 465cfu/hr and 461cfu/hr were observed in Female room-1 and room-2 respectively when compared to the acceptable range of 250-450cfu/hr. In this study only 3 isolates of S. pyogenes and 48 isolates of S. aureus were identified. Over 66% of S. aureus was identified in Critical Zone of Operating rooms. All isolates of S. aureus showed 100% and 82.8% resistance to methicillin and ampicillin respectively. CONCLUSION: Higher degree of aerobic bacterial load was measured from operating rooms' and surgical wards' indoor air. Reducing foot trafficking, improving the ventilation system and routine cleaning has to be made to maintain the aerobic bacteria load with in optimal level.
引用
收藏
页码:9 / 17
页数:9
相关论文
共 39 条
  • [1] Determination of the indoor air bacterial profile in Jimma University Specialized Hospital, Southwest Ethiopia
    Girma, Andualem
    Lamore, Yonas
    SAGE OPEN MEDICINE, 2022, 10
  • [2] INVASIVE BACTERIAL PATHOGENS AND THEIR ANTIBIOTIC SUSCEPTIBILITY PATTERNS IN JIMMA UNIVERSITY SPECIALIZED HOSPITAL, JIMMA, SOUTHWEST ETHIOPIA
    Zenebe, Tizazu
    Kannan, Subbaram
    Yilma, Daniel
    Beyene, Getenet
    ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2011, 21 (01) : 1 - 8
  • [3] BACTERIAL UROPATHOGENS IN URINARY TRACT INFECTION AND ANTIBIOTIC SUSCEPTIBILITY PATTERN IN JIMMA UNIVERSITY SPECIALIZED HOSPITAL, SOUTHWEST ETHIOPIA
    Beyene, Getenet
    Tsegaye, Wondewosen
    ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2011, 21 (02) : 141 - 146
  • [4] Indoor air bacterial load and antibiotic susceptibility pattern of isolates at Adare General Hospital in Hawassa, Ethiopia
    Atalay, Yibeltal Assefa
    Mengistie, Embialle
    Tolcha, Alemu
    Birhan, Belete
    Asmare, Getachew
    Gebeyehu, Natnael Atnafu
    Gelaw, Kelemu Abebe
    FRONTIERS IN PUBLIC HEALTH, 2023, 11
  • [5] REASONS AND OUTCOMES OF ADMISSIONS TO THE MEDICAL WARDS OF JIMMA UNIVERSITY SPECIALIZED HOSPITAL, SOUTHWEST ETHIOPIA
    Ali, Elias
    Woldie, Mirkuzie
    ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2010, 20 (02) : 113 - 120
  • [6] MICROBIOLOGICAL ASSESSMENT OF INDOOR AIR OF TEACHING HOSPITAL WARDS: A CASE OF JIMMA UNIVERSITY SPECIALIZED HOSPITAL
    Fekadu, Samuel
    Getachewu, Bahilu
    ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2015, 25 (02) : 117 - 122
  • [7] Bacterial contamination, bacterial profile and antimicrobial susceptibility pattern of isolates from stethoscopes at Jimma University Specialized Hospital
    Teklu Shiferaw
    Getenet Beyene
    Tesfaye Kassa
    Tsegaye Sewunet
    Annals of Clinical Microbiology and Antimicrobials, 12
  • [8] Bacterial contamination, bacterial profile and antimicrobial susceptibility pattern of isolates from stethoscopes at Jimma University Specialized Hospital
    Shiferaw, Teklu
    Beyene, Getenet
    Kassa, Tesfaye
    Sewunet, Tsegaye
    ANNALS OF CLINICAL MICROBIOLOGY AND ANTIMICROBIALS, 2013, 12
  • [9] High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest Ethiopia
    Gizaw, Zemichael
    Gebrehiwot, Mulat
    Yenew, Chalachew
    MULTIDISCIPLINARY RESPIRATORY MEDICINE, 2016, 11
  • [10] Multidrug-resistant bacterial isolates in infected wounds at Jimma University Specialized Hospital, Ethiopia
    Godebo, Girma
    Kibru, Gebre
    Tassew, Himanot
    ANNALS OF CLINICAL MICROBIOLOGY AND ANTIMICROBIALS, 2013, 12