A PULSING DEVICE FOR PACKED-BED BIOREACTORS .1. HYDRODYNAMIC BEHAVIOR

被引:14
|
作者
ROCA, E [1 ]
SANROMAN, A [1 ]
NUNEZ, MJ [1 ]
LEMA, JM [1 ]
机构
[1] UNIV SANTIAGO COMPOSTELA,DEPT CHEM ENGN,AVE CIENCIAS S-N,E-15706 SANTIAGO,SPAIN
来源
BIOPROCESS ENGINEERING | 1994年 / 10卷 / 02期
关键词
D O I
10.1007/BF00393388
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This paper describes a new pulsing device which permits the insertion in pulsing form of a liquid phase fed into an equipment where a microbial or enzymatic transformation occurs. It also analyzes the modifications of the flow model caused by the pulsation generated by means of three kinds of pulsators: A hydropneumatic pulsator, a selfpropelled pulsator and a newly designed elastic membrane pulsator. The hydrodynamic behaviour of a packed-bed column, to which each of these pulsators has been connected is compared with the correspondent system without pulsation. The flow model is determined by the study of the curves of residence times distribution, obtained by using a stimulus-response technique. A computer programme has been used to determine the axial dispersion coefficients from the response curves. In all cases we worked within a wide range of Re(p) (10-215). The pneumatic pulsing device causes a backmixing in the system due to the alternative movement that communicates to the fluid contained in the column. The application of the pulsation by means of the selfpropelled injector or the elastic membrane pulsator reduces the axial dispersion coefficient in regard to those corresponding to the system without pulsation, a fact which becomes even more significant when operating at high flow velocities. For the study of the hydraulic model of the pulsing system of elastic membrane we worked under different conditions in order to determine the effect of the particle's diameter, the viscosity, and the frequency of pulsation. At the same frequency at which the Re(p) increases, the axial dispersion coefficient also increases, following in all cases an almost linear tendency. For the same Re(p), the dispersion coefficient decreases when the particle diameter increases. On the other hand, the dispersion coefficients obtained for a fluid of a viscosity of 2 cp are, in some cases, up to 3 times higher than the corresponding values for water. All the results indicate that the new pulsator is specially applicable to reactors which, as in many biological transformations, present inhibitory problems by the product, or, in general, to those reactions that require that the flow model in the reactor be a plug flow model.
引用
收藏
页码:61 / 73
页数:13
相关论文
共 50 条
  • [1] A PULSING DEVICE FOR PACKED-BED BIOREACTORS .2. APPLICATION TO ALCOHOLIC FERMENTATION
    SANROMAN, A
    ROCA, E
    NUNEZ, MJ
    LEMA, JM
    BIOPROCESS ENGINEERING, 1994, 10 (02): : 75 - 81
  • [2] Influence of the tracer characteristics on hydrodynamic models of packed-bed bioreactors
    I. R. de Nardi
    M. Zaiat
    E. Foresti
    Bioprocess Engineering, 1999, 21 : 469 - 476
  • [3] Influence of the tracer characteristics on hydrodynamic models of packed-bed bioreactors
    de Nardi, IR
    Zaiat, M
    Foresti, E
    BIOPROCESS ENGINEERING, 1999, 21 (05) : 469 - 476
  • [4] Origins of pulsing regime in cocurrent packed-bed flows
    Wilhite, BA
    Blackwell, B
    Kacmar, J
    Varma, A
    McCready, MJ
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (16) : 6056 - 6066
  • [5] BEHAVIOR OF AN ADIABATIC PACKED-BED REACTOR .1. EXPERIMENTAL-STUDY
    BOS, ANR
    VANDEBELD, L
    OVERKAMP, JB
    WESTERTERP, KR
    CHEMICAL ENGINEERING COMMUNICATIONS, 1993, 121 : 27 - 53
  • [6] USE OF PACKED-BED BIOREACTORS APPLICATION TO ORES BIOLEACHING
    PORRO, S
    POGLIANI, C
    DONATI, E
    TEDESCO, P
    BIOTECHNOLOGY LETTERS, 1993, 15 (02) : 207 - 212
  • [7] Hydrodynamic evaluation of a biological packed-bed reactor
    Ribicki, Vinicius Gabriel
    Barana, Ana Claudia
    Vuitik, Guilherme
    ENGENHARIA SANITARIA E AMBIENTAL, 2024, 29
  • [8] Analysis of overall perchlorate removal rates in packed-bed bioreactors
    Logan, BE
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2001, 127 (05) : 469 - 471
  • [9] MODELS OF THE SOLID AND FLUID-MECHANICS IN PACKED-BED BIOREACTORS
    VERHOFF, FH
    FURGAMIC, JJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (SEP): : 42 - 42
  • [10] BEHAVIOR OF BIPOLAR PACKED-BED ELECTRODES
    GOODRIDGE, F
    KING, CJH
    WRIGHT, AR
    ELECTROCHIMICA ACTA, 1977, 22 (04) : 347 - 352