CINE MAGNETIC-RESONANCE-IMAGING AND COLOR DOPPLER FLOW MAPPING DISPLAYS OF FLOW VELOCITY, SPATIAL ACCELERATION, AND JET FORMATION - A COMPARATIVE IN-VITRO STUDY

被引:13
|
作者
SIMPSON, IA
MACIEL, BC
MOISES, V
SHANDAS, R
ELIAS, W
VALDESCRUZ, L
HESSELINK, JR
CHUNG, KJ
SAHN, DJ
机构
[1] OREGON HLTH SCI UNIV,UHN60,3181 SW SAM JACKSON PK RD,PORTLAND,OR 97201
[2] UNIV CALIF SAN DIEGO,DIV PEDIAT CARDIOL,LA JOLLA,CA 92093
关键词
D O I
10.1016/0002-8703(93)90670-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To study the effects of flow acceleration and high-velocity jets on the display characteristics of cine magnetic resonance imaging compared with color Doppler flow mapping, a custom-designed in vitro flow model was developed. This model consisted of a funnel segment tapering to an orifice (0.78 CM2) that leads into a confined receiving chamber with a second, discrete orifice (0.78 CM2) at its distal end. Cine magnetic resonance images obtained at varying flow rates (1.5 to 27.2 L/min) demonstrated loss of signal intensity throughout the tapering zone of spatial acceleration and a small zone of more marked signal loss immediately proximal to the second orifice (always <50% of the signal intensity within the tapering funnel zone) associated with more rapid spatial acceleration. A formed jet was imaged distal to the first orifice, and the turbulence area surrounding the laminar central jet core correlated well with flow rate (r = 0.98), as did the distance from the orifice to the subsequent onset of flow relaminarization (r = 0.96). A turbulent spray area was always seen distal to the second, discrete orifice. Comparative observations with color Doppler flow mapping and continuous wave Doppler demonstrated that signal intensity on cine magnetic resonance imaging is reduced by both spatial acceleration, and the high-velocity and turbulent jets associated with obstructive and regurgitant lesions. In vitro evaluation of cine magnetic resonance imaging allows comparative observations to be made about the flow characteristics of cine magnetic resonance imaging and color Doppler flow mapping and provides a more rational basis for the interpretation of cine magnetic resonance imaging in the clinical setting.
引用
收藏
页码:1165 / 1174
页数:10
相关论文
共 37 条
  • [21] AORTICO-LEFT VENTRICULAR TUNNEL - DIAGNOSIS BASED ON TWO-DIMENSIONAL ECHOCARDIOGRAPHY, COLOR FLOW DOPPLER IMAGING, AND MAGNETIC-RESONANCE-IMAGING
    HUMES, RA
    HAGLER, DJ
    JULSRUD, PR
    LEVY, JM
    FELDT, RH
    SCHAFF, HV
    MAYO CLINIC PROCEEDINGS, 1986, 61 (11) : 901 - 907
  • [22] A COMPARATIVE-STUDY OF VELOCITY-MEASUREMENTS IN MAJOR BLOOD-VESSELS USING MAGNETIC-RESONANCE-IMAGING AND DOPPLER ULTRASOUND
    ZANANIRI, FV
    JACKSON, PC
    HALLIWELL, M
    HARRIS, RA
    HAYWARD, JK
    DAVIES, ER
    WELLS, PNT
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (792): : 1128 - 1133
  • [23] Spatial factors for quantifying constant flow velocity in a small tube phantom: comparison of phase-contrast cine-magnetic resonance imaging and the intraluminal Doppler guidewire method
    Haruhiko Machida
    Yoshiaki Komori
    Eiko Ueno
    Yun Shen
    Masami Hirata
    Shinya Kojima
    Satoru Morita
    Munekuni Sato
    Takeshi Okazaki
    Japanese Journal of Radiology, 2009, 27 : 335 - 341
  • [24] Spatial factors for quantifying constant flow velocity in a small tube phantom: comparison of phase-contrast cine-magnetic resonance imaging and the intraluminal Doppler guidewire method
    Machida, Haruhiko
    Komori, Yoshiaki
    Ueno, Eiko
    Shen, Yun
    Hirata, Masami
    Kojima, Shinya
    Morita, Satoru
    Sato, Munekuni
    Okazaki, Takeshi
    JAPANESE JOURNAL OF RADIOLOGY, 2009, 27 (09): : 335 - 341
  • [25] Phase-Velocity Cine Magnetic Resonance Imaging Measurement of Pulsatile Blood Flow in Children and Young Adults: In Vitro and In Vivo Validation
    A.J. Powell
    S.E. Maier
    T. Chung
    T. Geva
    Pediatric Cardiology, 2000, 21 : 104 - 110
  • [26] Phase-velocity cine magnetic resonance imaging measurement of pulsatile blood flow in children and young adults: In vitro and in vivo validation
    Powell, AJ
    Maier, SE
    Chung, T
    Geva, T
    PEDIATRIC CARDIOLOGY, 2000, 21 (02) : 104 - 110
  • [27] APPLICATION OF COLOR DOPPLER FLOW MAPPING TO CALCULATE EFFECTIVE REGURGITANT ORIFICE AREA - AN IN-VITRO STUDY AND INITIAL CLINICAL OBSERVATIONS
    VANDERVOORT, PM
    RIVERA, JM
    MELE, D
    PALACIOS, IF
    DINSMORE, RE
    WEYMAN, AE
    LEVINE, RA
    THOMAS, JD
    CIRCULATION, 1993, 88 (03) : 1150 - 1156
  • [28] A comparative study of intraplacental villous arteries by latex cast model in vitro and color Doppler flow imaging in vivo
    Mu, JW
    Kanzaki, T
    Tomimatsu, T
    Fukuda, H
    Fujii, E
    Fuke, S
    Wasada, K
    Takeuchi, H
    Murata, Y
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2001, 27 (05) : 297 - 303
  • [29] Accurate measurement of pulsatile flow velocity in a small tube phantom: comparison of phase-contrast cine magnetic resonance imaging and intraluminal Doppler guidewire
    Machida, Haruhiko
    Komori, Yoshiaki
    Ueno, Eiko
    Shen, Yun
    Hirata, Masami
    Kojima, Shinya
    Sato, Munekuni
    Okazaki, Takeshi
    Masukawa, Ai
    Morita, Satoru
    Suzuki, Kazufumi
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (08): : 571 - 577
  • [30] Accurate measurement of pulsatile flow velocity in a small tube phantom: comparison of phase-contrast cine magnetic resonance imaging and intraluminal Doppler guidewire
    Haruhiko Machida
    Yoshiaki Komori
    Eiko Ueno
    Yun Shen
    Masami Hirata
    Shinya Kojima
    Munekuni Sato
    Takeshi Okazaki
    Ai Masukawa
    Satoru Morita
    Kazufumi Suzuki
    Japanese Journal of Radiology, 2010, 28 : 571 - 577