EFFECTS OF HYDRATION ON ELEMENTAL SENSITIVITIES IN NEUTRON-ACTIVATION ANALYSIS USING PROMPT AND DELAYED GAMMA-RAYS

被引:2
|
作者
ALAMIN, MB
SPYROU, NM
机构
[1] Department of Physics, University of Surrey, Guildford, GU2 5XH, Surrey
关键词
D O I
10.1007/BF02037734
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A 1.85x10(11) Bq (5Ci) Am/Be neutron source is being used to investigate the feasibility of applying the absolute method in the elemental analysis of bulk samples by instrumental neutron activation making use of prompt and delayed gamma rays. Among the different factors which might contribute to variations in sensitivity or in the uncertainty associated with the elemental concentration. is the presence of hydrogen in the sample. It is the purpose of this study to examine whether the presence of water in bulk samples such as landfill waste produces significant variations in measured elemental concentrations and if so, requires samples to be dried, which can be a time consuming and expensive process. The effect of hydration of samples on the sensitivity of ten elements has therefore been investigated. Samples with different water concentrations in a fixed volume and shape were prepared and used in the analysis in order to obtain a measure and an understanding of the effects involved.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [1] INVIVO NEUTRON-ACTIVATION ANALYSIS OF NITROGEN USING CAPTURE GAMMA-RAYS
    ETTINGER, KV
    BIGGIN, HC
    CHEN, NS
    CHETTLE, DR
    FREMLIN, JH
    HARVEY, TC
    MORGAN, WD
    NOWOTNY, R
    THOMAS, BJ
    VARTSKY, D
    KERNTECHNIK, 1975, 17 (02) : 89 - 92
  • [2] ELEMENTAL ANALYSIS USING CHARGED-PARTICLE INDUCED PROMPT GAMMA-RAYS
    PILLAY, AE
    BEWLEY, DK
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1984, 35 (05): : 353 - 358
  • [3] PROMPT-GAMMA NEUTRON-ACTIVATION ANALYSIS USING AN ISOTOPIC NEUTRON SOURCE
    TRUBERT, D
    ABBE, JC
    PAULUS, JM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1989, 134 (02): : 405 - 414
  • [4] A PROMPT GAMMA NEUTRON-ACTIVATION ANALYSIS FACILITY USING A DIFFRACTED BEAM
    HARLING, OK
    CHABEUF, JM
    LAMBERT, F
    YASUDA, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 83 (04): : 557 - 562
  • [5] THE PROMPT GAMMA NEUTRON-ACTIVATION ANALYSIS FACILITY AT MURR
    HANNA, AG
    BRUGGER, RM
    GLASCOCK, MD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 188 (03): : 619 - 627
  • [6] THE PHYSICAL BASIS FOR PROMPT GAMMA NEUTRON-ACTIVATION ANALYSIS
    CHRIEN, RE
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 43 : 253 - 255
  • [7] PROMPT ACTIVATION ANALYSIS OF COAL USING NEUTRON CAPTURE GAMMA RAYS
    RASMUSSEN, NC
    HUKAI, Y
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (01): : 29 - +
  • [8] ELEMENT SENSITIVITIES FOR ANALYSIS BY THERMAL-NEUTRON CAPTURE GAMMA-RAYS
    DUFFEY, D
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1971, 14 (02): : 931 - &
  • [9] INSITU CHARACTERIZATION OF HAZARDOUS CONTAMINANTS USING PROMPT GAMMA NEUTRON-ACTIVATION ANALYSIS
    RUDDY, FH
    CONGEDO, TV
    SEIDEL, JG
    GONZALEZ, JL
    WEIGLE, DH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 78 - NUCL
  • [10] ONLINE MEASUREMENTS OF BULK COAL USING PROMPT GAMMA NEUTRON-ACTIVATION ANALYSIS
    MARSHALL, JH
    ZUMBERGE, JF
    NUCLEAR GEOPHYSICS, 1989, 3 (04): : 445 - 459