Scattered radiation in flat-detector based cone-beam CT: Propagation of signal, contrast and noise into reconstructed volumes

被引:0
|
作者
Wiegert, Jens [1 ]
Hohmann, Steffen [1 ]
Bertram, Matthias [1 ]
机构
[1] Philips Res Labs, Weisshausstr 2, D-52066 Aachen, Germany
关键词
cone-beam computed tomography; X-ray scatter; Monte-Carlo simulations; noise propagation; contrast-to-noise; anti-scatter grids; scatter correction;
D O I
10.1117/12.710196
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a novel framework for the systematic assessment of the impact of scattered radiation in flat-detector based cone-beam CT. While it is well known that scattered radiation causes three different types of artifacts in reconstructed images (inhomogeneity artifacts such as cupping and streaks, degradation of contrast, and enhancement of noise), investigations in the literature quantify the impact of scatter mostly only in terms of inhomogeneity artifacts, giving little insight, e.g., into the visibility of low contrast lesions. Therefore, for this study a novel framework has been developed that in addition to normal reconstruction of the CT (HU) number allows for reconstruction of voxelized expectation values of three additional important characteristics of image quality: signal degradation, contrast reduction, and noise variances. The new framework has been applied to projection data obtained with voxelized Monte-Carlo simulations of clinical CT data sets of high spatial resolution. Using these data, the impact of scattered radiation was thoroughly studied for realistic and clinically relevant patient geometries of the head, thorax, and pelvis region. By means of spatially resolved reconstructions of contrast and noise propagation, the image quality of a scenario with using standard antiscatter grids could be evaluated with great detail. Results show the spatially resolved contrast degradation and the spatially resolved expected standard deviation of the noise at any position in the reconstructed object. The new framework represents a general tool for analyzing image quality in reconstructed images.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Cone-beam CT with a flat-panel detector: From image science to image-guided surgery
    Siewerdsen, Jeffrey H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S241 - S250
  • [42] Flat detector cone-beam CT-guided percutaneous needle biopsy of mediastinal lesions: preliminary experience
    Dechao Jiao
    Kai Huang
    Gang Wu
    Yanli Wang
    Xinwei Han
    La radiologia medica, 2016, 121 : 769 - 779
  • [43] Flat detector cone-beam CT-guided percutaneous needle biopsy of mediastinal lesions: preliminary experience
    Jiao, Dechao
    Huang, Kai
    Wu, Gang
    Wang, Yanli
    Han, Xinwei
    RADIOLOGIA MEDICA, 2016, 121 (10): : 769 - 779
  • [44] Vision-Based Intraoperative Cone-Beam CT Stitching for Non-overlapping Volumes
    Fuerst, Bernhard
    Fotouhi, Javad
    Navab, Nassir
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT I, 2015, 9349 : 387 - 395
  • [45] Ring artifact corrections in flat-panel detector based cone beam CT
    Abu Anas, Emran Mohammad
    Kim, Jaegon
    Lee, Soo Yeol
    Hasan, Md. Kamrul
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [46] Statistical weights for model-based reconstruction in cone-beam CT with electronic noise and dual-gain detector readout
    Wu, P.
    Stayman, J. W.
    Sisniega, A.
    Zbijewski, W.
    Foos, D.
    Wang, X.
    Aygun, N.
    Stevens, R.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (24):
  • [47] Image-based extraction of breathing signal from cone-beam CT projections
    Sabah, Shafiya
    Dhou, Salam
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [48] Spatial Resolution and Noise Prediction in Flat-Panel Cone-Beam CT Penalized-likelihood Reconstruction
    Wang, W.
    Gang, G. J.
    Siewerdsen, J. H.
    Stayman, J. W.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [49] Measurement-Based Cross-Scatter Correction in Dual Detector Cone-Beam CT
    Giles, W.
    Bowsher, J.
    Li, H.
    Yin, F.
    MEDICAL PHYSICS, 2011, 38 (06) : 3446 - +
  • [50] Effects of scattered radiation and beam quality on low contrast performance in cone beam breast CT - art. no. 614236
    Altunbas, M. Cem
    Shaw, Chris
    Chen, Lingyun
    Wang, Tianpeng
    Tu, Shuju
    Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : 14236 - 14236