Experimental study on distributed optical-fiber cable for high-pressure buried natural gas pipeline leakage monitoring

被引:34
|
作者
Zhou, Zhaoming [1 ]
Zhang, Jia [1 ]
Huang, Xuesong [2 ]
Guo, Xishui [2 ]
机构
[1] Southwest Petr Univ, Sch Mechatron Engn, Xindu Ave 8, Chengdu 610500, Sichuan, Peoples R China
[2] Petr Engn Technol Res Inst Sinopec Zhongyuan Oilf, Puyang 457000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical cable; Natural gas pipeline; Leak detection; Raman optical time domain reflect (ROTDR); Numerical analysis; SENSOR; OIL;
D O I
10.1016/j.yofte.2019.102028
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
At present, fiber-optic cable monitoring technology uses an fiber-optic cable located at 300 mm above a buried natural gas pipeline to collect gas leakage information. However, the change in soil temperature caused by natural gas leakage is not tested and verified. This prevents the installment of an fiber-optic cable for monitoring gas leakage in the field. To improve the sensitivity of fiber-optic cable leakage monitoring and reduce the failure rate, the laying mode of fiber-optic cable should be verified and analyzed. In this study, Peng-Robinson (PR) real gas state equation, a Raman optical time-domain reflectometer (ROTDR), and finite element method (FEM) were combined to simulate the gas leakage of buried pipelines. The trend of soil temperature around the leak hole and laying mode of fiber-optic cable was studied. It can be concluded that the higher the pressure of pipeline and leakage hole, the greater the temperature change at 100 mm directly above the pipeline. On this basis, a field test was carried out to study the leakage of a buried high-pressure natural gas pipeline. The experimental results show that the gas leakage can be detected by an fiber-optic cable located at 100 mm above the pipeline, and it is difficult to detect the change in soil temperature when the fiber-optic cable is located 200 mm or farther. The experimental results are consistent with the simulation results. This indicates that the simulation method is correct and feasible. Thus, the fiber-optic cable needs to be placed 100 mm or closer to the buried pipeline to monitor the temperature change. The result of the test and the simulation result are coincident approximately. The conclusion is: evenly lay 4 optical cables within 100 mm around the pipe, and each cable can monitor the temperature change in the 90 degrees range above the leakage hole. This method can accurately monitor the leakage of the whole pipe section. The study results can guide the laying plan of fiber-optic cables and construction of natural gas pipelines and prevent accidents.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Trend of soil temperature during pipeline leakage of high-pressure natural gas: Experimental and numerical study
    Zhou, Zhaoming
    Zhang, Jia
    Huang, Xuesong
    Zhang, Jie
    Guo, Xishui
    MEASUREMENT, 2020, 153
  • [2] Leakage and diffusion of high-pressure gas pipeline in soil and atmosphere: experimental and numerical study
    Jiang, Hongye
    Xie, Zhengyi
    Li, Youlv
    Chi, Minghua
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (04) : 10827 - 10842
  • [3] Leakage Simulation and Prediction for High-Pressure Natural Gas Pipeline in a Confined Space
    Xia, Zhiheng
    Xu, Zhao-Dong
    Lu, Hongfang
    Peng, Haoyan
    Liu, Xinyu
    Jia, Yankun
    JOURNAL OF PIPELINE SYSTEMS ENGINEERING AND PRACTICE, 2024, 15 (02)
  • [4] Experimental study on leakage temperature field of hydrogen blending into natural gas buried pipeline
    Zhu, Jianlu
    Wang, Sailei
    Pan, Jun
    Lv, Hao
    Zhang, Yixiang
    Han, Hui
    Liu, Cuiwei
    Duo, Zhili
    Li, Yuxing
    APPLIED ENERGY, 2024, 359
  • [5] Numerical and experimental study on the generation and propagation of negative wave in high-pressure gas pipeline leakage
    Yuan, Fang
    Zeng, Yan
    Luo, Rongmo
    Khoo, Boo Cheong
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2020, 65
  • [6] Distributed Optical Fiber Sensor Systems: Application to Natural Gas Pipeline Monitoring
    Lalam, Nageswara
    Bhatta, Hari
    Buric, Michael
    Ohodnicki, Paul
    Wright, Ruishu
    OPTICAL WAVEGUIDE AND LASER SENSORS III, 2024, 13044
  • [7] Numerical and experimental study on leakage detection for buried gas pipelines based on distributed optical fiber acoustic wave
    Zhang, Jia
    Lian, Zhanghua
    Zhou, Zhaoming
    Zhang, Jian
    Xiong, Ming
    Liu, Jiong
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (12)
  • [8] An Improved Distributed Optical Fiber Sensor (DOFS) for Monitoring Long-distance Buried Oil Pipeline Leakage and Intrusion
    Wang, Yannian
    Li, Zhengmin
    Jiang, Zhuangde
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 313 - +
  • [9] Distributed optical-fiber vibration sensor for the identification of pipeline leakage using relevant vector machine
    Li, Junchan
    Lu, Bo
    Wang, Yu
    Liu, Xin
    Bai, Qing
    Jin, Baoquan
    OPTICS FRONTIERS ONLINE 2020: DISTRIBUTED OPTICAL FIBER SENSING TECHNOLOGY AND APPLICATIONS, 2021, 11607
  • [10] Leakage detection in a buried gas pipeline based on distributed optical fiber time-domain acoustic wave signal
    Zhang, Jia
    Lian, Zhanghua
    Zhou, Zhaoming
    Song, Zijun
    Liu, Meng
    Yang, Kelong
    ENGINEERING FAILURE ANALYSIS, 2022, 141