A generalized 4D image registration scheme for targeted radionuclide therapy dosimetry

被引:8
|
作者
Papavasileiou, Periklis
Divoli, Antigoni
Hatziioannou, Kostas
Flux, Glenn D.
机构
[1] Papageorgiou Gen Hosp, Dept Phys Med, Thessaloniki 54603, Greece
[2] Inst Canc Res, Joint Dept Phys, Sutton, Surrey, England
[3] Royal Marsden Hosp NHS Fdn Trust, Sutton, Surrey, England
关键词
image registration; radionuclide therapy dosimetry; polynomial fitting;
D O I
10.1089/cbr.2007.310
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
An iterative, generalized four-dimensional (4D) method is presented in this paper that allows simultaneous registration of a series of single-photon emission computed tomography (SPECT) scans acquired in the course of a radionuclide therapy or pretherapy tracer study. The method combines temporal information with voxel-based similarity criteria to carry out simultaneous registration of the SPECT scans. A polynomial function was fitted to the maximum counts of each tumor site over the 4D study. Each tumor site was normalized to its maximum on the reference scan, and a template 4D dataset was generated, employing the polynomial fitting and the normalization map. Then, each 3D scan was registered to the corresponding simulated scan, using a 3D similarity criterion. The correlation coefficient (CC), the mutual information (MI), and the sum-of-absolute differences (SAD) similarity criteria were employed. Simulated data, based on a head-neck I-131-MIBG study, were used to compare the proposed method for 4D registration with sequential 3D registration. Sequential 3D registration resulted in residual registration errors of 3.5 +/- 2.5, 3.2 +/- 2.0, and 7.0 +/- 3.5 mm for the CC, MI, and SAD criteria respectively, whereas the corresponding 4D method gave errors of 2.4 +/- 1.6, 1.9 +/- 1.1, and 5.3 +/- 2.9 mm for the CC, MI, and SAD criteria, respectively. The 4D method was applied to Re-186 HEDP SPECT patient studies and registration was verified by a dual-cursor display tool.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [1] A generalized 4D image registration scheme for targeted radionuclide therapy dosimetry
    Papavasileiou, P.
    Divoli, A.
    Hatziioannou, K.
    Flux, G. D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S171 - S172
  • [2] The importance of the accuracy of image registration of SPECT images for 3D targeted radionuclide therapy dosimetry
    Papavasileiou, Periklis
    Divoli, Antigoni
    Hatziioannou, Konstantinos
    Flux, Glenn D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (24): : N539 - N548
  • [3] Image registration in the context of 3D SPECT dosimetry for radionuclide therapy
    Gleisner, Katarina Siogreen
    Ljungberg, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [4] Organs dosimetry in targeted radionuclide therapy
    Alnaaimi, Meshari
    Sulieman, Abdelmoneim
    Alkhorayef, Mohammed
    Salah, Hasan
    Alduaij, Musa
    Algaily, Mosab
    Alomair, O.
    Alashban, Y.
    Almohammad, H., I
    Bradley, David
    Kappas, C.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [5] ACCURATE DOSIMETRY FOR TARGETED RADIONUCLIDE THERAPY
    DEWHURST, SE
    RIGGS, SJ
    GREEN, AJ
    BEGENT, RHT
    BAGSHAWE, KD
    BRITISH JOURNAL OF CANCER, 1989, 59 (05) : 829 - 829
  • [6] Organs dosimetry in targeted radionuclide therapy
    Alnaaimi, Meshari
    Sulieman, Abdelmoneim
    Alkhorayef, Mohammed
    Salah, Hasan
    Alduaij, Musa
    Algaily, Mosab
    Alomair, O.
    Alashban, Y.
    Almohammad, H.I.
    Bradley, David
    Kappas, C.
    Radiation Physics and Chemistry, 2021, 188
  • [7] A novel four-dimensional image registration method for radionuclide therapy dosimetry
    Papavasileiou, P
    Flux, GD
    Guy, MJ
    Flower, MA
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (23): : 5373 - 5391
  • [8] Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images
    Ao, Edwin C. I.
    Wu, Nien-Yun
    Wang, Shyh-Jen
    Song, Na
    Mok, Greta S. P.
    MEDICAL PHYSICS, 2015, 42 (02) : 1060 - 1070
  • [9] 4D Medical Image Registration: A Survey
    Girija, J.
    Murthy, G. N. Krishna
    Reddy, P. Chenna
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON INTELLIGENT SUSTAINABLE SYSTEMS (ICISS 2017), 2017, : 539 - 547
  • [10] Adaptive Radiation Therapy with Deformable Image Registration and 4D Dose Calculation
    Ali, I.
    Alsbou, N.
    Ahmad, S.
    MEDICAL PHYSICS, 2021, 48 (06)