Establishing the Learning Curve of Robotic Sacral Colpopexy in a Start-up Robotics Program

被引:11
|
作者
Sharma, Shefali [1 ]
Calixte, Rose [2 ]
Finamore, Peter S. [1 ]
机构
[1] Winthrop Univ Hosp, Dept Obstet & Gynecol, Mineola, NY 11501 USA
[2] Winthrop Univ Hosp, Dept Biostat, Mineola, NY 11501 USA
关键词
Learning curve; Robotic sacral colpopexy;
D O I
10.1016/j.jmig.2015.08.886
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Study Objective: To determine the learning curve of the following segments of a robotic sacral colpopexy: preoperative setup, operative time, postoperative transition, and room turnover. Design: A retrospective cohort study to determine the number of cases needed to reach points of efficiency in the various segments of a robotic sacral colpopexy (Canadian Task Force II-2). Setting: A university-affiliated community hospital. Patients: Women who underwent robotic sacral colpopexy at our institution from 2009 to 2013 comprise the study population. Interventions: Patient characteristics and operative reports were extracted from a patient database that has been maintained since the inception of the robotics program at Winthrop University Hospital and electronic medical records. Based on additional procedures performed, 4 groups of patients were created (A-D). Measurements and Main Results: Learning curves for each of the segment times of interest were created using penalized basis spline (B-spline) regression. Operative time was further analyzed using an inverse curve and sequential grouping. A total of 176 patients were eligible. Nonparametric tests detected no difference in procedure times between the 4 groups (A-D) of patients. The preoperative and postoperative points of efficiency were 108 and 118 cases, respectively. The operative points of proficiency and efficiency were 25 and 36 cases, respectively. Operative time was further analyzed using an inverse curve that revealed that after 11 cases the surgeon had reached 90% of the learning plateau. Sequential grouping revealed no significant improvement in operative time after 60 cases. Turnover time could not be assessed because of incomplete data. Conclusions: There is a difference in the operative time learning curve for robotic sacral colpopexy depending on the statistical analysis used. The learning curve of the operative segment showed an improvement in operative time between 25 and 36 cases when using B-spline regression. When the data for operative time was fit to an inverse curve, a learning rate of II cases was appreciated. Using sequential grouping to describe the data, no improvement in operative time was seen after 60 cases. Ultimately, we believe that efficiency in operative time is attained after 30 to 60 cases when performing robotic sacral colpopexy. The learning curve for preoperative setup and postoperative transition, which is reflective of anesthesia and nursing staff, was approximately 110 cases. (C) 2016 AAGL. All rights reserved.
引用
收藏
页码:89 / 93
页数:5
相关论文
共 50 条
  • [21] Failure learning orientation and technology start-up performance
    Wilson G.A.
    Journal of High Technology Management Research, 2019, 30 (02):
  • [23] Deep Learning to Predict Start-Up Business Success
    Hsairi, Lobna
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2024, 15 (03) : 356 - 361
  • [24] Predicting Program Start-Up Using the Stages of Implementation Measure
    Saldana, Lisa
    Chamberlain, Patricia
    Wang, Wei
    Brown, C. Hendricks
    ADMINISTRATION AND POLICY IN MENTAL HEALTH AND MENTAL HEALTH SERVICES RESEARCH, 2012, 39 (06) : 419 - 425
  • [25] Peciko start-up caps total Indonesia Mahakam program
    不详
    OIL & GAS JOURNAL, 2000, 98 (42) : 50 - +
  • [26] PROGRAM MANAGEMENT IN DIESEL BUSINESS - SOME START-UP DECISIONS
    HEAD, TW
    MECHANICAL ENGINEERING, 1972, 94 (04) : 64 - &
  • [27] Predicting Program Start-Up Using the Stages of Implementation Measure
    Lisa Saldana
    Patricia Chamberlain
    Wei Wang
    C. Hendricks Brown
    Administration and Policy in Mental Health and Mental Health Services Research, 2012, 39 : 419 - 425
  • [28] SIMPLICITY OF DESIGN LEADS TO FAST LEARNING-CURVE FOR START-UP OF ROUND BILLET CASTER AT FALCK - ITALY
    MORANDO, M
    PEPI, G
    NARDACCI, M
    IRON AND STEEL ENGINEER, 1983, 60 (07): : 86 - 86
  • [29] Dynamic simulation of a HRSG system for a given start-up/shut down curve
    Cha, Hun
    Song, Yoo Seok
    Kim, Kyu Jong
    Kim, Jung Rae
    Kim, Sung Min
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 6, PTS A AND B, 2012, : 285 - 289
  • [30] Optimization and experiment study on start-up temperature control curve of turbine rotor
    Xu, Ning
    Wang, Qingchao
    Liu, Zhansheng
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2016, 52 (02): : 189 - 194