Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device

被引:57
|
作者
Nemeth, Gabor [1 ]
Vajas, Attila [1 ]
Kolozsvari, Bence [1 ]
Berta, Andras [1 ]
Modis, Laszlo [1 ]
机构
[1] Univ Debrecen, Med & Hlth Sci Ctr, Dept Ophthalmol, H-4012 Debrecen, Hungary
来源
关键词
D O I
10.1016/j.jcrs.2006.02.057
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare anterior chamber depth (ACD) measurements with a new optical device with those taken with a standard ultrasound (US) device in emmetropic phakic and pseudophakic eyes. SETTING: Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. METHODS: Forty-two phakic and 42 pseudophakic patients with normal axial lengths (mean 22.91 mm +/- 1.21 [SD]) were enrolled in the study. The ACD was measured 3 times with Scheimpflug-based Pentacam (Oculus) and then 3 times with a standard A-scan US device (AL-2000, Tomey). The data were then analyzed. RESULTS: In the phakic group, the mean ACID was 2.87 +/- 0.4 mm with the Pentacam and 2.89 +/- 0.49 mm with ultrasound A-scan (US) (P =.84). In the pseudophakic group, the mean ACD was 3.41 +/- 0.28 mm and 3.97 +/- 0.45 mm, respectively (P<.001). The correlation between measurements was significant in both the phakic and pseudophakic groups (r =.547/P<.001 and r =.404/P =.01, respectively). CONCLUSIONS: In phakic eyes, ACD measured with the Pentacam and with US was the same. However, in pseudophakic eyes, the difference was significantly lower when the ACD was measured with the Pentacam. Therefore, in pseudophakic patients, further evaluation of ACD data with the Scheimpflug-based system is necessary.
引用
收藏
页码:1331 / 1335
页数:5
相关论文
共 50 条
  • [21] Reply: Pseudophakic anterior chamber depth measurement
    M A Nanavaty
    S M Raj
    V A Vasavada
    V A Vasavada
    A R Vasavada
    Eye, 2009, 23 : 2120 - 2120
  • [22] Progression of Age Related Maculopathy in Phakic Versus Pseudophakic Eyes
    Kovacevic, Damir
    Vuceric, Tamara Misljenovic
    Caljkusic-Mance, Tea
    COLLEGIUM ANTROPOLOGICUM, 2010, 34 : 21 - 23
  • [23] Comparison of anterior chamber depth measurements using Galilei, HR Pentacam, and Orbscan II
    Salouti, Ramin
    Nowroozzadeh, Mohammad H.
    Zamani, Mohammad
    Ghoreyshi, Maryam
    Salouti, Rosa
    OPTOMETRY-JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 2010, 81 (01) : 35 - 39
  • [24] Comparability and intra-/interobserver reliability of anterior chamber depth measurements with the Pentacam and IOLMaster
    Savant, Vijay
    Chavan, Randhir
    Pushpoth, Sreekumari
    Ilango, B.
    JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (06) : 615 - 618
  • [25] FIAT: A Device for Objective, Optical Measures of Accommodation in Phakic and Pseudophakic Eyes
    Roorda, Austin
    Tiruveedhula, Pavan
    Naseri, Ayman
    Rhee, Paul
    Clarke, Matt
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (01):
  • [26] Clinical measurements of peripheral contrast sensitivity in elderly phakic and pseudophakic eyes
    Alarcon, Aixa
    Canovas, Carmen
    Van der Mooren, Marrie
    Janakiraman, Priya
    Rosen, Robert
    Lundstrom, Linda
    Chang, Daniel H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [27] Anterior chamber depth measurement using Pentacam and Biograph in children
    Hashemi, Hassan
    Heydarian, Samira
    Khabazkhoob, Mehdi
    Emamian, Mohammad Hassan
    Yekta, Abbasali
    Fotouhi, Akbar
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2022, 105 (06) : 582 - 586
  • [28] Evaluation of the agreement between pentacam and ultrasound biomicroscopy measurements of anterior chamber depth in chinese patients with primary angle-closure glaucoma
    Liang, Juan
    Liu, Wei
    Xing, Xiaoli
    Liu, Hua
    Zhao, Shaozhen
    Ji, Jian
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (04) : 361 - 362
  • [29] Evaluation of the agreement between pentacam and ultrasound biomicroscopy measurements of anterior chamber depth in chinese patients with primary angle-closure glaucoma
    Juan Liang
    Wei Liu
    Xiaoli Xing
    Hua Liu
    Shaozhen Zhao
    Jian Ji
    Japanese Journal of Ophthalmology, 2010, 54 : 361 - 362
  • [30] Posterior Chamber Phakic Intraocular Lens Implantation in Eyes with an Anterior Chamber Depth of Less Than 3 mm: A Multicenter Study
    Kazutaka Kamiya
    Kimiya Shimizu
    Akihito Igarashi
    Yoshihiro Kitazawa
    Takashi Kojima
    Tomoaki Nakamura
    Kazuo Ichikawa
    Scientific Reports, 8