Effects of a magnetic palatal expansion appliance with reactivation system: An animal experiment

被引:5
|
作者
Tong, Fei [1 ]
Liu, Fen [1 ]
Liu, Jiali [1 ]
Xiao, Chang [1 ]
Liu, Jian [1 ]
Wu, Jianyong [1 ]
机构
[1] Nanchang Univ, Affiliated Stomatol Hosp, Dept Orthodont, Nanchang, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
NEODYMIUM-IRON-BORON; FORCE APPLICATION; DIAMOND; POINTS; FIELDS;
D O I
10.1016/j.ajodo.2016.06.030
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to evaluate the effects of a newly designed magnetic palatal expansion appliance with a reactivation system. Methods: A magnetic palatal expansion appliance was designed based on the repulsion forces of neodymium-iron-boron magnets combined with a reactivation system. Eighteen prepubertal male beagle dogs were assigned randomly to the magnetic expansion (ME) group, the mechanical screw expansion (SE) group, or the control group. Two pairs of nonmagnetic metal bone marker implants were inserted into palatal bone bilaterally 3 mm lateral to the midpalatal suture and in line with the first and fourth premolars, respectively, in each dog. The 6 animals in each group received (1) newly designed magnetic expanders, (2) jackscrew expanders, or (3) no expansion appliance. Expansion was stopped after 4 weeks when 6 mm of activation was achieved in the 2 treated groups. Three-dimensional evaluations of dental and skeletal effects were performed with cone-beam computed tomography. Histologic examinations were conducted using light microscopy to observe morphologic changes in the midpalatal suture after hematoxylin and eosin staining. Results: The absolute transversal changes of both treated groups before and after expansion were significantly greater than those in the control group in all parameters (P < 0.001). The differences of the distances of bilateral canines in the ME group were significantly greater than in the SE group (1.04 +/- 0.16 mm; P < 0.001); the differences of the distances between implants adjacent to the first premolars (0.77 +/- 0.06 mm; P < 0.001) and the distances between implants adjacent to the fourth premolars (0.37 +/- 0.06 mm; P < 0.001) in the SE group were significantly greater than in the ME group. Histologic observations of the palatal sutures in the ME and SE groups, when compared with the control group, showed widening of the sutures and many fibroblasts in an active, proliferative state. Counts of osteoblasts were increased in both expansion groups. Counts of osteoclasts were increased in the SE group. Conclusions: Both appliances expanded the maxilla effectively and induced processes of bone remodeling of the midpalatal sutures during expansion. The new magnetic palatal expansion appliances produced a smaller skeletal effect and a greater dental effect than did the mechanical screw palatal expansion appliances.
引用
收藏
页码:132 / 142
页数:11
相关论文
共 50 条
  • [21] EFFECTS OF A FIXED MAGNETIC APPLIANCE ON THE DENTOFACIAL COMPLEX
    KALRA, V
    BURSTONE, CJ
    NANDA, R
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1989, 95 (06) : 467 - 478
  • [22] Short-term effects of strain produced on a split palatal screw-type hyrax appliance after rapid maxillary expansion: A clinical trial
    Javier Garcia, Valentin
    Comesana, Rafael
    Kasem, Khaled
    Maria Usrtell-Torrent, Josep
    Badaoui, Aida
    Cristina Manzanares-Cespedes, Maria
    Carvalho-Lobatoe, Patricia
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 148 (06) : 990 - 998
  • [23] THE STABILITY OF THE ARCH-EXPANSION EFFECTS OF FRANKEL APPLIANCE THERAPY
    HIME, DL
    OWEN, AH
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1990, 98 (05) : 437 - 445
  • [24] Effects of Surgical and Nonsurgical Rapid Maxillary Expansion on Palatal Structures
    Kurt, Gokmen
    Altug, Ayse Tuba
    Turker, Gokhan
    Kilic, Banu
    Kilic, Erdem
    Alkan, Alper
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (03) : 775 - 780
  • [25] A Magnetic Field-based Appliance Metering System
    Rajagopal, Niranjini
    Giri, Suman
    Berges, Mario
    Rowe, Anthony
    2013 ACM/IEEE INTERNATIONAL CONFERENCE ON CYBER-PHYSICAL SYSTEMS (ICCPS), 2013, : 229 - 238
  • [26] Effects of a magnetic appliance in functional class III patients
    Tuncer, C
    Üner, O
    ANGLE ORTHODONTIST, 2005, 75 (05) : 768 - 777
  • [27] Effects of a bonded rapid maxillary expansion appliance during orthodontic treatment
    Memikoglu, TUT
    Iseri, H
    ANGLE ORTHODONTIST, 1999, 69 (03) : 251 - 256
  • [28] A retrospective cephalometric study on pharyngeal airway space changes after rapid palatal expansion and Herbst appliance with or without skeletal anchorage
    Antonio Manni
    Marco Pasini
    Maria Rita Giuca
    Riccardo Morganti
    Mauro Cozzani
    Progress in Orthodontics, 17
  • [29] A retrospective cephalometric study on pharyngeal airway space changes after rapid palatal expansion and Herbst appliance with or without skeletal anchorage
    Manni, Antonio
    Pasini, Marco
    Giuca, Maria Rita
    Morganti, Riccardo
    Cozzani, Mauro
    PROGRESS IN ORTHODONTICS, 2016, 17
  • [30] Case report: Modified use of the Jasper Jumper appliance in a skeletal Class II mixed dentition case requiring palatal expansion
    Mills, CM
    McCulloch, KJ
    ANGLE ORTHODONTIST, 1997, 67 (04) : 277 - 282