Bypass line assisted start-up of a loop heat pipe with a flat evaporator

被引:19
|
作者
Boo, Joon Hong [1 ]
Jung, Eui Guk [2 ]
机构
[1] Korea Aerosp Univ, Sch Aerosp & Mech Engn, Goyang 412791, Gyeonggi Do, South Korea
[2] Korea Aerosp Univ, Grad Sch, Dept Aerosp & Mech Engn, Goyang 412791, Gyeonggi Do, South Korea
关键词
Loop heat pipe; Flat evaporator; Start-up; Bypass line; MENISCUS TYPE EVAPORATOR; THERMAL PERFORMANCE;
D O I
10.1007/s12206-009-0405-5
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Loop heat pipes often experience start-up problems especially under low thermal loads. A bypass line was installed between the evaporator and the liquid reservoir to alleviate the difficulties associated with start-up of a loop heat pipe with flat evaporator. The evaporator and condenser had dimensions of 40 mm (W) by 50 mm (L). The wall and tube materials were stainless steel and the working fluid was methanol. Axial grooves were provided in the flat evaporator to serve as vapor passages. The inner diameters of liquid and vapor transport lines were 2 mm and 4 mm, respectively, and the length of the two lines was 0.5 m each. The thermal load range was up to 130 W for horizontal alignment with the condenser temperature of 10A degrees C. The experimental results showed that the minimum thermal load for start-up was lowered by 37% when the bypass line was employed.
引用
收藏
页码:1613 / 1619
页数:7
相关论文
共 50 条
  • [1] Bypass line assisted start-up of a loop heat pipe with a flat evaporator
    Joon Hong Boo
    Eui Guk Jung
    Journal of Mechanical Science and Technology, 2009, 23 : 1613 - 1619
  • [2] Start-up and temperature fluctuation of loop heat pipe with flat disk evaporator
    Xu M.
    Tao S.
    Qi C.
    Liang L.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2023, 42 (09): : 4531 - 5437
  • [3] Start-Up Characteristic Simulation of a Flat-Plat Loop Heat Pipe
    Wang X.
    Hu Q.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2021, 54 (06): : 645 - 650
  • [4] Experimental investigation on the start-up performance of a novel flat loop heat pipe with dual evaporators
    He, Song
    Ma, Zhengyuan
    Deng, Weizhong
    Zhang, ZiKang
    Guo, Ziqi
    Liu, Wei
    Liu, Zhichun
    ENERGY REPORTS, 2022, 8 : 7500 - 7507
  • [5] Effects of evaporator wettability on the start-up and heat transfer performance of an oscillating heat pipe
    Chinchedu, Raghuvaran
    Kupireddi, Kiran Kumar
    Chandramohan, V. P.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2025, 39 (01) : 453 - 463
  • [6] Liquid-vapor phase behavior and operating characteristics of the capillary evaporator of a loop heat pipe at start-up
    Nishikawara, M.
    Otani, K.
    Ueda, Y.
    Yanada, H.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 129 : 426 - 433
  • [7] Experimental investigation on the start-up performance of a loop heat pipe with three flat disk evaporators combined
    Wu, Tong
    Wang, Tingting
    Ma, Zhengyuan
    Zhang, Zikang
    Liu, Wei
    Liu, Zhichun
    APPLIED THERMAL ENGINEERING, 2022, 216
  • [8] Start-up characteristics of flatten loop heat pipe using in LED
    School of Chemistry and Chemical Engineering, Sun Yat-Sen University, Guangzhou 510275, China
    Kung Cheng Je Wu Li Hsueh Pao, 2009, 10 (1759-1762):
  • [9] Investigation of low power start-up characteristics of a loop heat pipe
    Kaya, T
    Ku, JT
    Hoang, TT
    Cheung, MK
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM - 1999, PTS ONE AND TWO, 1999, 458 : 799 - 804
  • [10] Investigation of instability on loop heat pipe with flat evaporator
    Gai, Dongxing
    Yin, Yang
    Chen, Chen
    FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467