Multi active tuned mass dampers for earthquake-induced vibration response control of high rise building

被引:1
|
作者
Huu, Thang Pham [1 ]
Miura, Nanako [1 ]
Iba, Daisuke [1 ]
机构
[1] Kyoto Inst Technol, Fac Mech Engn, Sakyo Ku, Kyoto, Kyoto 6068585, Japan
关键词
Active structural control; Active tuned mass damper; Fuzzy logic controller; Seismic response; Genetic algorithm; FUZZY-LOGIC CONTROL;
D O I
10.1007/s12206-022-0304-6
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper discusses the advantages of the multi active tuned mass dampers (MATMD) for vibration control of multi-degree-freedom structures and their distribution masses. The 11-story building having two ATMDs at different story and different ATMD mass under long and short period earthquakes is considered. A structural system with ATMDs using fuzzy logic control was simulated against the ground motion of the earthquakes. The time history of the story displacements and accelerations, and the frequency responses of both the uncontrolled and controlled structures are shown in this study to investigate the effectiveness of multiple ATMDs compared with single ATMD and distributed multiple tuned mass dampers (d-MTMDs). The gained results also present the effect of mass distribution of two ATMDs and their location on the building response that the distributed MATMD with same mass has better performance than the distributed MATMD with different mass and single ATMD in the most earthquake cases.
引用
收藏
页码:1655 / 1666
页数:12
相关论文
共 50 条
  • [21] Combined Tuned Mass Dampers for structural vibration control
    Cao, Huong Quoc
    INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2023, 157
  • [22] Tuned Mass Dampers for Wind-Induced Vibration Control of Chongqi Bridge
    Sun, Zhen
    Zou, Zilong
    Ying, Xuyong
    Li, Xianqi
    JOURNAL OF BRIDGE ENGINEERING, 2020, 25 (01)
  • [23] Pendulum tuned mass dampers for floor vibration control
    Setareh, M
    Ritchey, JK
    Baxter, AJ
    Murray, TM
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2006, 20 (01) : 64 - 73
  • [24] VIBRATION CONTROL USING MULTIPLE TUNED MASS DAMPERS
    IGUSA, T
    XU, K
    JOURNAL OF SOUND AND VIBRATION, 1994, 175 (04) : 491 - 503
  • [25] Wind-induced excitation control of a tall building with tuned mass dampers
    Kim, Young-Moon
    You, Ki-Pyo
    Kim, Han-Young
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2008, 17 (03): : 669 - 682
  • [26] Semi-Active Tuned Mass Dampers for Vibration Control of Random Crowd Load
    Wang, Liangkun
    Zhou, Ying
    Shi, Weixing
    Tongji Daxue Xuebao/Journal of Tongji University, 2024, 52 (10): : 1483 - 1491
  • [27] Seismic-induced vibration control of a multi-story building with double tuned mass dampers considering soil-structure interaction
    Araz, Onur
    Elias, Said
    Kablan, Feyza
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 166
  • [28] ROBUST OPTIMUM DESIGN OF TUNED MASS DAMPERS FOR HIGH-RISE BUILDINGS SUBJECT TO WIND-INDUCED VIBRATION
    Rossato, Bibiana Bertolin
    Fadel Miguel, Letcia Fleck
    NUMERICAL ALGEBRA CONTROL AND OPTIMIZATION, 2023, 13 (01): : 154 - 168
  • [29] Bending vibration control of a ball screw via multi-tuned mass dampers
    Beijing Municipal Key Lab of Advanced Manufacturing Technology, College of Mechanical Engineering and Applied Electronic Technology, Beijing University of Technology, Beijing
    100124, China
    J Vib Shock, 10 (63-67):
  • [30] STRUCTURAL CONTROL USING ACTIVE TUNED MASS DAMPERS
    ABDELROHMAN, M
    JOURNAL OF THE ENGINEERING MECHANICS DIVISION-ASCE, 1981, 107 (05): : 990 - 990