Self-assembly pipette tip-based cigarette filters for micro-solid phase extraction of ketoconazole cis-enantiomers in urine samples followed by high-performance liquid chromatography/diode array detection

被引:27
|
作者
Andrade, Roseane Teixeira [1 ]
Santos da Silva, Ricky Cassio [1 ]
Pereira, Arnaldo Cesar [1 ]
Borges, Keyller Bastos [1 ]
机构
[1] Univ Fed Sao Joao del Rei, Dept Ciencias Nat, Sao Joao Del Rei, MG, Brazil
关键词
DISPLACEMENT SORPTION PRECONCENTRATION; WATER SAMPLES; SEPARATION; DRUGS; INHIBITION; CYP3A4; PALLADIUM; LEAD; HPLC; RAT;
D O I
10.1039/c5ay00468c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple stereoselective HPLC/DAD method was developed for the determination of ketoconazole (KTZ) cis-enantiomers in human urine. In addition, the potential use of pipette tip-based cigarette filters for micro-solid phase extraction (PT-CFs-m-SPE) of KTZ cis-enantiomers in human urine samples prior to HPLC/DAD was studied in this paper. In order to find a suitable procedure for extraction of KTZ cis-enantiomers in human urine, various parameters that probably affect the extraction efficiency including the washing solvent, eluent kind and volume, pH, quantity of the material, sample volume and ionic strength were systematically optimized. Optimum chromatographic separations among the KTZ cis-enantiomers have been achieved within 10 minutes using a Chiralpak (R) IA column (100 x 4.6 mm, 3 mm) as the stationary phase with a mobile phase consisting of 100% ethanol at a flow rate of 1 mL min(-1). Detection was performed at 250 nm. The performance criteria for linearity, sensitivity, precision, accuracy, recovery, robustness and stability have been assessed and were within the recommended guidelines. The mean extraction recoveries/relative standard deviation for (+)-(2R, 4S)-KTZ and (-)-(2S, 4R)-KTZ were 100.74 +/- 9.52% and 106.90 +/- 9.26%, respectively. The method showed to be linear over the concentration range of 12.5 to 400 ng mL(-1) for each enantiomer with the correlation coefficients of 0.9946 and 0.9910, for (+)-(2R, 4S)-KTZ and (-)-(2S, 4R)-KTZ, respectively. Within-day and between-day precision and accuracy assays for these analytes were studied at three concentration levels and were lower than 15%. The method was successfully employed in a preliminary cumulative urinary excretion study after administration of racemic cis-KTZ to a healthy volunteer.
引用
收藏
页码:7270 / 7279
页数:10
相关论文
共 50 条
  • [1] A Self-Assembly Pipette Tip Restricted Access Mesoporous Polypyrrole Solid-Phase Extraction Coupled With Capillary Electrophoresis With Diode Array Detection for the Determination of Enalapril in Urine Samples
    Carvalho, Iara Amorim
    Silva, Camilla Fonseca
    Borges, Keyller Bastos
    ELECTROPHORESIS, 2025,
  • [2] Dispersive Micro-Solid Phase Extraction Combined with High-Performance Liquid Chromatography for the Determination of Three Penicillins in Milk Samples
    Noorfatimah Yahaya
    Mohd Marsin Sanagi
    Takahito Mitome
    Norikazu Nishiyama
    Wan Aini Wan Ibrahim
    Hadi Nur
    Food Analytical Methods, 2015, 8 : 1079 - 1087
  • [3] Dispersive Micro-Solid Phase Extraction Combined with High-Performance Liquid Chromatography for the Determination of Three Penicillins in Milk Samples
    Yahaya, Noorfatimah
    Sanagi, Mohd Marsin
    Mitome, Takahito
    Nishiyama, Norikazu
    Ibrahim, Wan Aini Wan
    Nur, Hadi
    FOOD ANALYTICAL METHODS, 2015, 8 (05) : 1079 - 1087
  • [4] The Application of Pipette-Tip and Magnetic Dummy-Template Molecularly Imprinted Solid-Phase Extraction Coupled with High-Performance Liquid Chromatography with Diode Array and Spectrofluorimetric Detection for the Determination of Coumarins in Cosmetic Samples
    Spackova, Andrea
    Hrobonova, Katarina
    Jablonsky, Michal
    PROCESSES, 2024, 12 (03)
  • [5] Determination of organic acids in dried Actinidia arguta by pipette tip-based micro matrix solid-phase dispersion coupled with high performance liquid chromatography
    Cong, Xina
    Xu, Heran
    Yan, Miao
    Qian, Guanlin
    Liang, Xiaoman
    Pan, Aijuan
    Pan, Song
    Wang, Yuanpeng
    Xin, Guang
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 136
  • [6] Pipette-tip micro-solid phase extraction based on melamine-foam@polydopamine followed by ultra-high-performance liquid chromatography-quadrupole-time-of-flight mass spectrometry for detection of psychotropic drugs in human serum
    He, Xiaodan
    Sun, Tangqiang
    Wang, Ling
    Jiang, Xuehua
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1163
  • [7] Pipette-tip micro-solid phase extraction based on melamine-foam@polydopamine followed by ultra-high-performance liquid chromatography–quadrupole–time-of-flight mass spectrometry for detection of psychotropic drugs in human serum
    He, Xiaodan
    Sun, Tangqiang
    Wang, Ling
    Jiang, Xuehua
    Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences, 2021, 1163
  • [8] A Polyacrylate Cotton-based Pipette Tip Micro-solid-phase Extraction Technique Coupled with High-performance Liquid Chromatography for Carvedilol Determination in Aqueous Media
    Poryan, Golchin
    Noori, Maedeh
    Talebpour, Zahra
    Aboul-Enein, Hassan Y.
    CURRENT ANALYTICAL CHEMISTRY, 2024, 20 (08) : 569 - 581
  • [9] Analysis of benzoylurea insecticides in water samples with TiO2 nanotube array micro-solid phase extraction coupled to high performance liquid chromatography
    Zhou, Qingxiang
    Wu, Wei
    Huang, Yunrui
    RSC ADVANCES, 2014, 4 (86) : 45946 - 45952
  • [10] Cigarette filters as adsorbents of solid-phase extraction for determination of fluoroquinolone antibiotics in environmental water samples coupled with high-performance liquid chromatography
    Chen, Bo
    Wang, Weidong
    Huang, Yuming
    TALANTA, 2012, 88 : 237 - 243