A teleoperated control approach for anthropomorphic manipulator using magneto-inertial sensors

被引:0
|
作者
Noccaro, A. [1 ]
Cordella, F. [2 ]
Zollo, L. [2 ]
Di Pino, G. [1 ]
Guglielmelli, E. [2 ]
Formica, D. [1 ,2 ]
机构
[1] Univ Campus Biomed, Dept Med, Unit Neurophysiol & Neuroengn Human Technol Inter, Via Alvaro del Portillo 21, I-00128 Rome, Italy
[2] Univ Campus Biomed, Dept Engn, Unit Biomed Robot & Biomicrosyst, Via Alvaro del Portillo 21, I-00128 Rome, Italy
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this paper we propose and validate a teleoperated control approach for an anthropomorphic redundant robotic manipulator, using magneto-inertial sensors (IMUs). The proposed method allows mapping the motion of the human arm (used as the master) on the robot end-effector (the slave). We record arm movements using IMU sensors, and calculate human forward kinematics to be mapped on robot movements. In order to solve robot kinematic redundancy, we implemented different algorithms for inverse kinematics that allows imposing anthropomorphism criteria on robot movements. The main objective is to let the user to control the robotic platform in an easy and intuitive manner by providing the control input freely moving his/her own arm and exploiting redundancy and anthropomorphism criteria in order to achieve human-like behaviour on the robot arm. Therefore, three inverse kinematics algorithms are implemented: Damped Least Squares (DLS), Elastic Potential (EP) and Augmented Jacobian (AJ). In order to evaluate the performance of the algorithms, four healthy subjects have been asked to control the motion of an anthropomorphic robot arm (i.e. the Kuka Light Weight Robot 4+) through four magneto-inertial sensors (i.e. Xsens Wireless Motion Tracking sensors - MTw) positioned on their arm. Anthropomorphism indices and position and orientation errors between the human hand pose and the robot end-effector pose were evaluated to assess the performance of our approach.
引用
收藏
页码:156 / 161
页数:6
相关论文
共 50 条
  • [1] Technical challenges using magneto-inertial sensors for gait analysis
    Gastaldi, L.
    Rosso, V.
    Gabola, V.
    Agostini, V.
    Frutos, M. M. Lovagnini
    Knaflitz, M.
    Takeda, R.
    Tadano, S.
    2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 274 - 279
  • [2] Estimation of the center of rotation using wearable magneto-inertial sensors
    Crabolu, M.
    Pani, D.
    Raffo, L.
    Cereatti, A.
    JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 3928 - 3933
  • [3] Accurately measuring human movement using magneto-inertial sensors: techniques and challenges
    Cereatti, Andrea
    Trojaniello, Diana
    Della Croce, Ugo
    2015 2ND IEEE INTERNATIONAL SYMPOSIUM ON INERTIAL SENSORS AND SYSTEMS (ISISS), 2015, : 121 - 124
  • [4] Evaluation of the accuracy in the determination of the center of rotation by magneto-inertial sensors
    Crabolu, Michele
    Pani, Danilo
    Cereatti, Andrea
    2016 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS 2016) PROCEEDINGS, 2016, : 501 - 505
  • [5] An alignment procedure for ambulatory measurements of lower limb kinematic using magneto-inertial sensors
    Taffoni, F.
    Piervirgili, G.
    Formica, D.
    Guglielmelli, E.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 1197 - 1200
  • [6] Elbow joint kinematics during cricket bowling using magneto-inertial sensors: A feasibility study
    Wells, Denny
    Alderson, Jacqueline
    Camomilla, Valentina
    Donnelly, Cyril
    Elliott, Bruce
    Cereatti, Andrea
    JOURNAL OF SPORTS SCIENCES, 2019, 37 (05) : 515 - 524
  • [7] Magneto-inertial Approach to Direct-drive Laser Fusion
    O. V. Gotchev
    N. W. Jang
    J. P. Knauer
    M. D. Barbero
    R. Betti
    C. K. Li
    R. D. Petrasso
    Journal of Fusion Energy, 2008, 27 : 25 - 31
  • [8] An experimental protocol for the definition of upper limb anatomical frames on children using magneto-inertial sensors
    Ricci, L.
    Formica, D.
    Tamilia, E.
    Taffoni, F.
    Sparaci, L.
    Capirci, O.
    Guglielmelli, E.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 4903 - 4906
  • [9] Magneto-inertial approach to direct-drive laser fusion
    Gotchev, O. V.
    Jang, N. W.
    Knauer, J. P.
    Barbero, M. D.
    Betti, R.
    Li, C. K.
    Petrasso, R. D.
    JOURNAL OF FUSION ENERGY, 2008, 27 (1-2) : 25 - 31
  • [10] Validation of Magneto-Inertial Measurement Units for Upper-Limb Motion Analysis Through an Anthropomorphic Robot
    Lapresa, Martina
    Tamantini, Christian
    di Luzio, Francesco Scotto
    Ferlazzo, Marco
    Sorrenti, Gianfranco
    Corpina, Flavio
    Zollo, Loredana
    IEEE SENSORS JOURNAL, 2022, 22 (17) : 16920 - 16928