Understanding sidewall constraint involving ventilation effects on temperature distribution of fire-induced thermal flow under a tunnel ceiling

被引:35
|
作者
Zhou, Tiannian [1 ]
Li, Haihang [2 ]
Chen, Qinpei [1 ]
Wei, Ruichao [1 ]
Wang, Jian [1 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
[2] China Jiliang Univ, Sch Qual & Safety Engn, Safety & Environm Inst, Hangzhou, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Tunnel fire; Arced ceiling; Constraint effect; Ventilation; Temperature; MAXIMUM SMOKE TEMPERATURE; HEPTANE POOL FIRES; ROAD TUNNEL; FLAME CHARACTERISTICS; GAS TEMPERATURE; LOCATIONS; UPSTREAM; MOVEMENT; DISTANCE; CHANNEL;
D O I
10.1016/j.ijthermalsci.2018.03.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study focused on temperature distribution of thermal flow under an arced ceiling, induced by a pool fire impinging on the sidewall of tunnels with natural ventilation. A sequence of full-scale simulations were carried out for fires against the sidewall with decreasing transverse distances from 7 to 0.5 m and considering five different wind velocities from 0 to 2 m/s. The differences in temperature distribution between the arced ceiling and flat ceiling are compared and analyzed. The simulated values are also compared to the previous results from full-scale tests and empirical models. The results show that the longitudinal temperatures beneath the flat ceiling are lower than those beneath the arced ceiling when x/H-ef > 1, owing to a greater heat loss in the movement process. For the arced ceiling, the correlation between the normalized ceiling jet temperature rise and the dimensionless transverse distance can still fit an exponential function, but the constraint effect of the sidewall is more significant compared to that in the flat ceiling because there exists a transition from a weak plume to a strong plume as the transverse distance is reduced. In addition, a modified correlation is proposed to predict the maximum temperature rise under an arced ceiling in the range of H-L < H-ef wherein different transverse fire locations and ventilation velocities are considered simultaneously.
引用
收藏
页码:290 / 300
页数:11
相关论文
共 34 条
  • [31] Study on the Temperature Distribution and Thermal Damage of Concrete Lining in the Maximum Temperature Section of Tunnel Under Fire Condition
    Xi, Baoping
    Wu, Yangchun
    Chen, Luhai
    Guo, Qinghua
    Zhu, Hehua
    PROCEEDINGS OF GEOSHANGHAI 2018 INTERNATIONAL CONFERENCE: TUNNELLING AND UNDERGROUND CONSTRUCTION, 2018, : 612 - 624
  • [32] Numerical study on the smoke temperature distribution beneath the ceiling of a single-ended sealing tunnel under the condition of double fire sources
    Ma, Qiuju
    Chen, Jianhua
    You, Jingfeng
    He, Ya
    Zhang, Zhaokun
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 52
  • [33] Experimental investigation on ceiling temperature characteristics induced by weak and strong fire plumes in tunnel fires equipped with two-point extraction ventilation using smoke extraction channel
    Zhao, Peng
    Yuan, Zhongyuan
    Liang, Chenchen
    Yuan, Yanping
    Xie, Yuanyi
    Yu, Nanyang
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2022, 124
  • [34] Numerical investigation of longitudinal location and heat release rate of fire source on neutral plane height and induced flow in longitudinal sloping tunnel fires under natural ventilation
    Shao, Zhuyu
    Li, Yi
    Cui, Haihao
    Yu, Binshan
    Cong, Haiyong
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 200