External Calibration of the Spectral Coverage for Three-Dimensional Multispectral MRI

被引:19
|
作者
Kaushik, S. Sivaram [1 ]
Marszalkowski, Cathy [2 ]
Koch, Kevin M. [1 ,2 ]
机构
[1] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Dept Radiol, 8700 W Wisconsin Ave, Milwaukee, WI 53226 USA
关键词
spectral-calibration; MAVRIC-SL; frequency map; 3D-MSI; METAL ARTIFACT CORRECTION; FAST SPIN-ECHO; HIP-ARTHROPLASTY; IMPLANTS; IMPACT;
D O I
10.1002/mrm.26065
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: By combining images created at distinct frequency offsets from the Larmor frequency, three-dimensional (3D) multispectral imaging (3D-MSI) sequences help overcome the large spatial frequency dispersion caused by metal implants. This frequency dispersion, however, varies with the implant size, orientation, and composition. Using a MAVRIC 3D-MSI acquisition, we sought to prospectively calibrate the spectral coverage needed for 3D-MSI scans. This calibration should offer a significant improvement to image quality, and reduce the scan time. Methods: The 24 spectral bins from the calibration scan were used to generate a map of frequency offsets around the implant. The magnitude image was used to remove any outliers in the associated frequency offset map, and this processed map was used to determine the cutoff frequency offset and, hence, number of spectral bins. This approach was tested in 13 subjects, by retrospectively reconstructing MAVRIC-SL images with fewer spectral bins. Subsequently, the spectral coverage for MAVRIC-SL images was prospectively calibrated in six subjects, and based on the cutoff frequency offset, these images were acquired with fewer spectral bins. Results: With fewer spectral bins, both retrospectively and prospectively calibrated MAVRIC-SL images adequately delineated the implant boundary. Conclusion: Incorporating this calibration procedure into future 3D-MSI exams will help improve image signal-to-noise ratio, reduce scan time, and significantly improve clinical workflow when imaging near orthopedic implants. (C) 2015 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1494 / 1503
页数:10
相关论文
共 50 条
  • [1] Three-Dimensional Magnetometer Calibration With Small Space Coverage for Pedestrians
    Wahdan, Ahmed
    Georgy, Jacques
    Noureldin, Aboelmagd
    IEEE SENSORS JOURNAL, 2015, 15 (01) : 598 - 609
  • [2] Multispectral imaging with three-dimensional rosette trajectories
    Bucholz, Elizabeth K.
    Song, Jiayu
    Johnson, Allan
    Hancu, Ileana
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) : 581 - 589
  • [3] Coverage and Connectivity in Three-Dimensional Networks
    Alam, S. M. Nazrul
    Haas, Zygmunt J.
    MOBICOM 2006, 2006, : 346 - 357
  • [4] The Design of Linear Three-Dimensional Calibration
    Guo, Dequan
    Zhang, Xinrui
    Ju, Hui
    Liu, Hong
    Chen, Jin
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND AUTOMATIC CONTROL, 2016, 367 : 791 - 799
  • [5] Multispectral three-dimensional digital infrared thermal imaging
    Xiao, H
    Zhang, YB
    Wang, AB
    OPTICAL ENGINEERING, 2003, 42 (04) : 906 - 911
  • [6] Compression of multispectral images by three-dimensional SPIHT algorithm
    Dragotti, PL
    Poggi, C
    Ragozini, ARP
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2000, 38 (01): : 416 - 428
  • [7] Assessment of three-dimensional acetabular coverage angles
    Upasani, Vidyadhar V.
    Bomar, James D.
    Bandaralage, Harsha
    Doan, Joshua D.
    Farnsworth, Christine L.
    JOURNAL OF HIP PRESERVATION SURGERY, 2020, 7 (02): : 305 - 312
  • [8] Three-Dimensional MRI of the Musculoskeletal System
    Naraghi, Ali
    White, Lawrence M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (03) : W283 - W293
  • [10] Spectral tomography of three-dimensional objects
    Bulygin, FV
    Levin, GG
    OPTIKA I SPEKTROSKOPIYA, 1995, 79 (06): : 973 - 978