Lung-Optimized Deep- Learning-Based Reconstruction for Ultralow-Dose CT

被引:13
|
作者
Goto, Makoto [1 ]
Nagayama, Yasunori [2 ]
Sakabe, Daisuke [1 ]
Emoto, Takafumi [1 ]
Kidoh, Masafumi [2 ]
Oda, Seitaro [2 ]
Nakaura, Takeshi [2 ]
Taguchi, Narumi [2 ]
Funama, Yoshinori [3 ]
Takada, Sentaro [2 ]
Uchimura, Ryutaro [2 ]
Hayashi, Hidetaka [2 ]
Hatemura, Masahiro [1 ]
Kawanaka, Koichi [2 ]
Hirai, Toshinori [2 ]
机构
[1] Kumamoto Univ Hosp, Dept Cent Radiol, Chuo Ku, Kumamoto 8608556, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, 1-1-1 Honjo,Chuo Ku, Kumamoto 8608556, Japan
[3] Kumamoto Univ, Fac Life Sci, Dept Med Radiat Sci, Chuo Ku, Kumamoto 8620976, Japan
关键词
CT; Lung; Deep-learning; Image reconstruction; Ultralow-dose; FILTERED BACK-PROJECTION; SUBMILLISIEVERT CHEST CT; TASK-BASED PERFORMANCE; ITERATIVE-RECONSTRUCTION; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; ALGORITHMS; PHANTOM;
D O I
10.1016/j.acra.2022.04.025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To evaluate the image properties of lung-specialized deep-learning-based reconstruction (DLR) and its appli-cability in ultralow-dose CT (ULDCT) relative to hybrid-(HIR) and model-based iterative-reconstructions (MBIR).Materials and Methods: An anthropomorphic chest phantom was scanned on a 320-row scanner at 50-mA (low-dose-CT 1 [LDCT-1]), 25-mA (LDCT-2), and 10-mA (ULDCT). LDCT were reconstructed with HIR; ULDCT images were reconstructed with HIR (ULDCT-HIR), MBIR (ULDCT-MBIR), and DLR (ULDCT-DLR). Image noise and contrast-to-noise ratio (CNR) were quantified. With the LDCT images as reference standards, ULDCT image qualities were subjectively scored on a 5-point scale (1 = substantially inferior to LDCT-2, 3 = compara-ble to LDCT-2, 5 = comparable to LDCT-1). For task-based image quality analyses, a physical evaluation phantom was scanned at seven doses to achieve the noise levels equivalent to chest phantom; noise power spectrum (NPS) and task-based transfer function (TTF) were evaluated. Clinical ULDCT (10-mA) images obtained in 14 nonobese patients were reconstructed with HIR, MBIR, and DLR; the subjective acceptability was ranked. Results: Image noise was lower and CNR was higher in ULDCT-DLR and ULDCT-MBIR than in LDCT-1, LDCT-2, and ULDCT-HIR (p < 0.01). The overall quality of ULDCT-DLR was higher than of ULDCT-HIR and ULDCT-MBIR (p < 0.01), and almost comparable with that of LDCT-2 (mean score: 3.4 +/- 0.5). DLR yielded the highest NPS peak frequency and TTF50% for high-contrast object. In clinical ULDCT images, the subjective acceptability of DLR was higher than of HIR and MBIR (p < 0.01).Conclusion: DLR optimized for lung CT improves image quality and provides possible greater dose optimization opportunity than HIR and MBIR.
引用
收藏
页码:431 / 440
页数:10
相关论文
共 50 条
  • [1] Prospective evaluation of deep learning image reconstruction for Lung-RADS and automatic nodule volumetry on ultralow-dose chest CT
    Yoo, Seung-Jin
    Park, Young Sik
    Choi, Hyewon
    Kim, Da Som
    Goo, Jin Mo
    Yoon, Soon Ho
    PLOS ONE, 2024, 19 (02):
  • [2] Deep learning-based image domain reconstruction enhances image quality and pulmonary nodule detection in ultralow-dose CT with adaptive statistical iterative reconstruction-V
    Ye, Kai
    Xu, Libo
    Pan, Boyang
    Li, Jie
    Li, Meijiao
    Yuan, Huishu
    Gong, Nan-Jie
    EUROPEAN RADIOLOGY, 2025,
  • [3] Ultralow-dose CT imaging with deep learning noise reduction on EXPLORER total-body PET/CT scanner
    Ahlquist, Jesse
    Abdelhafez, Yasser
    Nardo, Lorenzo
    Badawi, Ramsey
    Qi, Jinyi
    Wang, Guobao
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [4] The evaluation of the reduction of radiation dose via deep learning-based reconstruction for cadaveric human lung CT images
    Miyata, Tomo
    Yanagawa, Masahiro
    Kikuchi, Noriko
    Yamagata, Kazuki
    Sato, Yukihisa
    Yoshida, Yuriko
    Tsubamoto, Mitsuko
    Tomiyama, Noriyuki
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [5] The evaluation of the reduction of radiation dose via deep learning-based reconstruction for cadaveric human lung CT images
    Tomo Miyata
    Masahiro Yanagawa
    Noriko Kikuchi
    Kazuki Yamagata
    Yukihisa Sato
    Yuriko Yoshida
    Mitsuko Tsubamoto
    Noriyuki Tomiyama
    Scientific Reports, 12
  • [6] Model-based vs hybrid iterative reconstruction technique in ultralow-dose submillisievert CT colonography
    Lambert, L.
    Ourednicek, P.
    Jahoda, J.
    Lambertova, A.
    Danes, J.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1048):
  • [7] Submilisievert ultralow-dose CT colonography using iterative reconstruction technique: a feasibility study
    Lambert, Lukas
    Danes, Jan
    Jahoda, Jiri
    Masek, Martin
    Lisy, Jiri
    Ourednicek, Petr
    ACTA RADIOLOGICA, 2015, 56 (05) : 517 - 525
  • [8] Model-Based Iterative Reconstruction Technique for Ultralow-Dose Computed Tomography of the Lung A Pilot Study
    Yamada, Yoshitake
    Jinzaki, Masahiro
    Tanami, Yutaka
    Shiomi, Eisuke
    Sugiura, Hiroaki
    Abe, Takayuki
    Kuribayashi, Sachio
    INVESTIGATIVE RADIOLOGY, 2012, 47 (08) : 482 - 489
  • [9] BEST IN PHYSICS (IMAGING): Prospective Control of Prior-Image Based Reconstruction for Ultralow-Dose CT: Application in Lung Nodule Surveillance
    Zhang, H.
    Gang, G. J.
    Lin, C. T.
    Stayman, J. W.
    MEDICAL PHYSICS, 2018, 45 (06) : E703 - E703
  • [10] Sub-milliSievert ultralow-dose CT colonography with iterative model reconstruction technique
    Lambert, Lukas
    Ourednicek, Petr
    Briza, Jan
    Giepmans, Walter
    Jahoda, Jiri
    Hruska, Lukas
    Danes, Jan
    PEERJ, 2016, 4