Study on the Effect of Temperature on the Alignment of a Long-Span Steel-Concrete Composite Beam Track Cable-Stayed Bridge

被引:0
|
作者
Li, Xiaogang [1 ]
Huang, Xiangsheng [1 ]
Ding, Peng [2 ]
Chen, Xiaohu [2 ]
Wang, Qiansong [1 ]
Cen, Sihan [1 ]
机构
[1] Chongqing Univ Sci & Technol, Sch Civil & Hydraul Engn, Chongqing 400074, Peoples R China
[2] TY Lin Int Engn Consulting China Co Ltd, Chongqing 401121, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 22期
关键词
temperature effect; steel-concrete composite beam; track cable-stayed bridge; bridge alignment;
D O I
10.3390/app142210688
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In order to study the effect of temperature on the alignment of a long-span special track bridge, this paper provides a theoretical basis and technical support for bridge design, construction and later operation. This research established the section model of the steel-hybrid beam by COMSOL, and the internal temperature field, transverse temperature, and vertical temperature gradient were analyzed. The Midas Civil bridge model analysis system was established to investigate the influence of temperature difference and temperature gradient on the vertical deformation of the whole bridge. Based on the temperature and displacement monitoring system of the Chongqing Nanjimen track bridge, the temperature and displacement data in 2023 were obtained for comparative analysis. The results show that the temperature field inside the composite beam presents a nonlinear distribution, the daily temperature difference can reach 26.0 degrees C, and there is a significant temperature gradient between the steel beam and the concrete. The highest temperature is 60.3 degrees C at 15:00 when the temperature difference between the upper and lower edges of the concrete slab is 11.1 degrees C, and the daily transverse temperature gradient is 3.2 degrees C, 5.3 degrees C and 7.4 degrees C, respectively. Under the temperature difference in the system, the maximum displacement of the main beam is 92.3 mm, and the mid-span displacement is 132.1 mm under the positive temperature difference. Based on the measured data for the whole year, it is found that the displacement of the main beam under the combined action of ambient temperature and solar radiation significantly exceeds the influence of a single temperature. The research shows that temperature change has an important impact on the stability and durability of the bridge, and temperature monitoring and management should be strengthened in the design and operation stage to ensure the bridge's safety and smooth operation of the train.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Prediction Study on the Alignment of a Steel-Concrete Composite Beam Track Cable-Stayed Bridge
    Li, Xiaogang
    Luo, Haoran
    Ding, Peng
    Chen, Xiaohu
    Tan, Shulin
    BUILDINGS, 2023, 13 (04)
  • [2] Characteristics of Interaction between Tracks and Long-span Cable-stayed Bridge with Steel-concrete Composite Beam
    Yan, Bin
    Xie, Haoran
    Pan, Wenbin
    Hao, Shuo
    Journal of Railway Engineering Society, 2019, 36 (09): : 11 - 16
  • [3] Study of Mechanical Property of Main Girder for Long-Span Steel-Concrete Composite Girder Cable-Stayed Bridge
    Chen, Guo-Hong
    Xu, Zhao
    Bridge Construction, 2019, 49 (05) : 39 - 44
  • [4] Mechanical Behavior of Steel-Concrete Joint in a Bidirectional Curved Pylon of a Long-Span Cable-Stayed Bridge
    Shi, Zhou
    Zhong, Meiling
    Gu, Jiachang
    Jiang, Feng
    Zhang, Tongzhuo
    JOURNAL OF BRIDGE ENGINEERING, 2023, 28 (03)
  • [5] Study on the Mechanical Behavior of Bi-directionally Curved Composite Pylon Steel-concrete Joints for a Long-span Cable-stayed Bridge
    Shi Z.
    Gu J.-C.
    Yu W.-Q.
    Tang Q.-H.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2022, 35 (06): : 73 - 85
  • [6] Crack Resistance of Steel-Concrete Hybrid Joint between Concrete Girder and Steel-Concrete Composite Girder in Long-Span Cable-Stayed Bridge under Hogging Moment
    Liang, Huanwei
    Tan, Ke
    Deng, Kailai
    Zhang, Yongming
    Zhao, Canhui
    Yang, Tengyu
    JOURNAL OF BRIDGE ENGINEERING, 2023, 28 (02)
  • [7] Study on the Long-span Cable-stayed Bridge Composite Beam Hoisting Construction Technology in China
    Li, Xinxing
    2015 2nd International Conference on Education and Education Research (EER 2015), Pt 3, 2015, 7 : 141 - 146
  • [8] Study on Static and Dynamic Characteristics Analysis of Long Span Steel Concrete Composite Beam Cable-stayed Bridge
    Tian, Wusheng
    Liang, Bin
    Jin, Xingliang
    PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (ICEESD 2017), 2017, 129 : 185 - 188
  • [9] Analysis of Temperature Filed and Thermal Effect in Long-Span Composite Girder Cable-Stayed Bridge
    Zhou, Hao
    Yi, Yue-Lin
    Ye, Zhong-Tao
    Li, Ming
    Bridge Construction, 2020, 50 (05) : 50 - 55
  • [10] Elastoplastic Analysis on Seismic Response of Long-Span Composite Beam Cable-Stayed Bridge
    Mohammed, Al-Jaboobi
    Zhen, Shi-Xiong
    Maged, Al-Sebaeai
    Al-Bukhaiti, Khalil
    13TH INTERNATIONAL CONFERENCE ON ROAD AND AIRFIELD PAVEMENT TECHNOLOGY 2023, 2023, : 272 - 286