COGENERATION SYSTEMS EVALUATION: A CASE STUDY.

被引:0
|
作者
Kirby, Kevin A.
Rich, John F.
Mahoney, Paul J.
机构
来源
Engineering News-Record | 1981年
关键词
COST EFFECTIVENESS - EVALUATION;
D O I
暂无
中图分类号
学科分类号
摘要
The feasibility of a cogeneration plant hinges on the balance of steam and power obtained for a particular application, the terms of purchase and sale of power to the local utility, and the investment required. A comparative design analysis was developed for the uprating and refurbishing of an industrial co-generation facility. The plant requirements were specified as 245,000 pounds per hour of process steam at 135 spig, and 83 megawatts of electrical power. The existing power generation system included four gas turbine driven generators with waste heat boilers, and steam plant consisting of 7 fired boilers. The generators were radially connected to a 40 mw 2400 v substation. Two generators were connected to each of two buses, which in turn supplied power to the chemical plant and power house through a radial distribution system.
引用
收藏
相关论文
共 50 条
  • [21] Comparative study of power and water cogeneration systems
    Bouzayani, N.
    Galanis, N.
    Orfi, J.
    DESALINATION, 2007, 205 (1-3) : 243 - 253
  • [22] Dysmenorrhea: A Case Study.
    Monisha, R.
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2016, 7 (05): : 114 - 116
  • [23] AM - A CASE STUDY.
    Schardein, C.
    Thakkar, G.
    Amajoyi, R.
    DISEASES OF THE COLON & RECTUM, 2022, 65 (05) : 120 - 120
  • [24] CIM: A CASE STUDY.
    Merhib, Jordan D.
    Circuits manufacturing, 1987, 27 (11):
  • [25] PROTOTYPING CASE STUDY.
    Smith, Peter M.
    Journal of Information Systems Management, 1985, 2 (03): : 20 - 25
  • [26] Bond strength evaluation of adhesive systems on dentin. A comparative study.
    Sinhoreti, MAC
    DeGoes, MF
    Consani, S
    Sobrinho, LC
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 986 - 986
  • [27] Cogeneration systems
    2000, PennWell Publ Co, Tulsa, OK, USA (08):
  • [28] Cogeneration systems
    Nakao, M
    Tsutsui, K
    Ogata, T
    Takakusagi, A
    NTT REVIEW, 1997, 9 (04): : 30 - 37
  • [29] High aperture and wide field of view optical systems: A case study.
    Zuin, A
    Gadda, C
    Leone, V
    Greco, V
    Molesini, G
    DESIGN AND ENGINEERING OF OPTICAL SYSTEMS, 1996, 2774 : 363 - 368
  • [30] Simulating protection systems: Effects on voltage dips and reliability, a case study.
    Bloemhof, GA
    Leitloff, V
    SEVENTH INTERNATIONAL CONFERENCE ON DEVELOPMENTS IN POWER SYSTEM PROTECTION, 2001, (479): : 258 - 261