The simulation for ultrasonic testing based on frequency-phase coded excitation

被引:0
|
作者
Zhao X. [1 ]
Zhang J. [1 ,2 ]
Cong S. [3 ]
Gang T. [2 ]
机构
[1] School of Material Science and Engineering, Dalian Jiaotong University, 794 Huanghe Road, Dalian
[2] State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin
[3] Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang
基金
中国国家自然科学基金;
关键词
Coded excitation; K-wave; Pulse compression; Simulation; Ultrasonic testing;
D O I
10.1504/IJCMSSE.2019.101664
中图分类号
学科分类号
摘要
Large time-bandwidth product coded signal and pulse compression are introduced into ultrasonic testing. Linear frequency modulation (LFM) excitation is usually used to improve time resolution, but sidelobe should be suppressed to detect smaller flaws nearby. Barker coded excitation is usually used to suppress sidelobe, but time resolution of results is lower than LFM excitation. So frequency-phase coded excitation is proposed to obtain higher time resolution and lower sidelobe level. The proposed excitation signal is applying LFM to each sub-pulse of Barker code, and it is called LFM-B13. The results of simulations demonstrate that, time resolution of LFM-B13 excitation is approximately 40% higher than that of LFM excitation, and main sidelobe level of LFM-B13 excitation is approximately 4 dB lower than that of LFM excitation, when 60% bandwidth of 5 MHz central frequency transducers are used. Copyright © 2019 Inderscience Enterprises Ltd.
引用
收藏
页码:37 / 47
页数:10
相关论文
共 50 条
  • [31] Optimization of ultrasonic elastography by coded excitation and transmit-side multi-frequency compounding
    Zhi-hong Zhang
    Hao-lin Liu
    Ying-ni He
    Dong-quan Liu
    Journal of Central South University, 2014, 21 : 1003 - 1010
  • [32] Optimization of ultrasonic elastography by coded excitation and transmit-side multi-frequency compounding
    Zhang Zhi-hong
    Liu Hao-lin
    He Ying-ni
    Liu Dong-quan
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2014, 21 (03) : 1003 - 1010
  • [33] Optimization of ultrasonic elastography by coded excitation and transmit-side multi-frequency compounding
    张志宏
    刘昊霖
    何颖妮
    刘东权
    JournalofCentralSouthUniversity, 2014, 21 (03) : 1003 - 1010
  • [34] FREQUENCY-PHASE SCANNING OF THE QUASI-OPTICAL FOCUSING SYSTEM
    TKACHUK, VP
    RADIOTEKHNIKA I ELEKTRONIKA, 1986, 31 (05): : 877 - 882
  • [35] FREQUENCY-PHASE CONTROLLED DIRECT VOLTAGE CONVERTER ANALYZERS
    BELOV, GA
    ELECTRICAL TECHNOLOGY, 1985, (04): : 12 - 23
  • [36] Frequency-phase method of a thermal diffusivity definition of materials
    Skripnik, Y
    Yurchik, G
    MODERN PROBLEMS OF RADIO ENGINEERING, TELECOMMUNICATIONS AND COMPUTER SCIENCE, PROCEEDINGS, 2002, : 149 - 150
  • [37] INVESTIGATION OF UNCERTAINTY FUNCTION OF A SIGNAL WITH FREQUENCY-PHASE MANIPULATION
    OSTROUKHOV, VS
    TUZOV, GI
    RADIOTEKHNIKA I ELEKTRONIKA, 1974, 19 (11): : 2309 - 2313
  • [38] Estimation of ultrasonic attenuation in a bone using coded excitation
    Nowicki, A
    Litniewski, J
    Secomski, W
    Lewin, PA
    Trots, I
    ULTRASONICS, 2003, 41 (08) : 615 - 621
  • [39] Coded excitation ultrasonic needle tracking: An in vivo study
    Xia, Wenfeng
    Ginsberg, Yuval
    West, Simeon J.
    Nikitichev, Daniil I.
    Ourselin, Sebastien
    David, Anna L.
    Desjardins, Adrien E.
    MEDICAL PHYSICS, 2016, 43 (07) : 4065 - 4073
  • [40] The design and implementation of coded excitation in ultrasonic endoscope system
    Opto-electronic Information Science and Technology Laboratory, Ministry of Education, College of Precision Instrument and Opto-electronic Engineering, Tianjin University, Tianjin 300072, China
    Guangdianzi Jiguang, 2009, 2 (279-282):