Improved performance of a shunt hybrid active power filter by a robust exponential functional link network-based nonlinear adaptive filter control to enhance power quality

被引:1
|
作者
Daramukkala, Pavankumar [1 ]
Mohanty, Kanungo Barada [1 ]
Behera, Bhanu Pratap [1 ]
机构
[1] Natl Inst Technol, Dept Elect Engn, Rourkela, India
关键词
Power Quality; Harmonic mitigation; Reactive power sharing; Shunt Hybrid Active Power Filter; Nonlinear adaptive filtering; ALGORITHM; DESIGN; SYSTEM; SERIES;
D O I
10.1016/j.isatra.2024.05.036
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This research article details the design and implementation of a nonlinear adaptive filtering (NAF) technique using an exponential functional link network (EFLN) for a shunt hybrid active power filter (SHAPF) control to solve the current-associated power quality issues on the utility side at the distribution level of electrical power systems. Separation of the fundamental component from the harmonics, achieving unity power factor operation, reducing the reactive power drawn from the source, balancing the currents during transients, and reduction of total harmonic distortion (THD) of the source current are the issues considered to resolve. The proposed technique solves these issues by generating the sinusoidal reference current and separating the fundamental current from the harmonics. When compared to conventional and existing adaptive filtering techniques such as least mean square (LMS), least mean fourth (LMF), and variable step size LMS (VSS-LMS), the proposed EFLN-NAF method excels in terms of speedy convergence, adaptability in noise-specific environments and reduced steady-state coefficient error. MATLAB/Simulink software is utilized to perform the simulations to examine the suggested strategy for the chosen SHAPF topology both in static and dynamic scenarios. For a 15 kW and 3kVAr requirement of the nonlinear load, simulation results proved that the designed PPF for 2kVAr is able to share the reactive power with the APF, thereby reducing its rating and cost. The proposed method of filtering has been proven to be fast converging with 0.049 s, and the THD in steady state is brought to 1.32 % in steady-state and to 3.77 % during transient conditions, which are under standard limits. A hardware prototype of the experimental setup is constructed at the laboratory scale with OPAL-RT (OP4510) as the controller. With an active and reactive power demand of 1.1 kW and 210VAr, the designed PPF supplies 110 VAr, whereas the rest is supplied by the APF. The practical THD in source current is observed to be 2.081 %, which meets the standards. The results from both simulations and experiments are validated, and the efficacy of the proposed technique in mitigating the aforementioned power quality issues is proved.
引用
收藏
页码:324 / 349
页数:26
相关论文
共 50 条
  • [31] A Robust LQG Servo Control Strategy of Shunt-Active Power Filter for Power Quality Enhancement
    Panigrahi, Rakhee
    Subudhi, Bidyadhar
    Panda, Prafulla Chandra
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (04) : 2860 - 2869
  • [32] Adaptive and Exact Linearization Control of Multicellular Power Converter Based on Shunt Active Power Filter
    Boubakeur Rouabah
    Lazhar Rahmani
    Houari Toubakh
    Eric Duviella
    Journal of Control, Automation and Electrical Systems, 2019, 30 : 1019 - 1029
  • [33] Adaptive and Exact Linearization Control of Multicellular Power Converter Based on Shunt Active Power Filter
    Rouabah, Boubakeur
    Rahmani, Lazhar
    Toubakh, Houari
    Duviella, Eric
    JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2019, 30 (06) : 1019 - 1029
  • [34] An improved shunt-hybrid-type active power filter and its control method
    Zhou, Ke
    Wang, Kai
    Liu, Lu
    Tan, Qi
    Chu, Hongbo
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2012, 32 (30): : 67 - 72
  • [35] Power Quality Enhancement in a Distribution Network Using PSO Assisted Kalman Filter - Based Shunt Active Power Filter
    Prince, Satyavarta Kumar
    Panda, Kaibalya Prasad
    Kumar, Vulisi Narendra
    Panda, Gayadhar
    2018 IEEMA ENGINEER INFINITE CONFERENCE (ETECHNXT), 2018,
  • [36] A Nonlinear Control Strategy for Hybrid Active Power Filter
    Han Wei
    Zhou Lili
    Wang Dazhi
    Li Yunlu
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 3596 - 3599
  • [37] Performance Enhancement of Shunt Active Power Filter Application using Adaptive Neural Network
    Govind, Annu
    Prakash, Anupama
    Kumar, Prakash
    JOURNAL OF POWER TECHNOLOGIES, 2021, 101 (01): : 78 - 85
  • [38] Optimization control of DC link voltage for shunt active power filter
    Xie, Bin
    Dai, Ke
    Zhang, Shuquan
    Kang, Yong
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2011, 31 (09): : 23 - 29
  • [39] Immunity of shunt active power filter based on improved LADRC
    Yin, Yupeng
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2024, 46 (02) : 326 - 333
  • [40] Fuzzy Logic Control of Shunt Active Power Filter for Power Quality Improvement
    Anjana, S.
    Maya, P.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SOFT COMPUTING SYSTEMS, ICSCS 2015, VOL 1, 2016, 397 : 975 - 985