A variable refrigerant flow (VRF) system is widely applied to build air conditioning systems. Literature review of previous VRF modeling studies was conducted, and it was found that the current calculation approach in EnergyPlus can result in more than 20% deviation in both heat transfer capacity and power consumption. Therefore, a new VRF model is proposed in this study, which includes an improved thermal zone distribution concept, new indoor unit types, and a new thermodynamic model. The developed model is validated with experimental data within 10% in heat transfer capacity and 5% in power consumption. Based on the proposed model, the operation control strategy is also discussed. The results show that the proposed model could also simulate the current control strategy in the VRF system.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Development and validation of a new variable refrigerant flow system model in EnergyPlus
    Hong, Tianzhen
    Sun, Kaiyu
    Zhang, Rongpeng
    Hinokuma, Ryohei
    Kasahara, Shinichi
    Yura, Yoshinori
    ENERGY AND BUILDINGS, 2016, 117 : 399 - 411
  • [2] Modelling of a Variable Refrigerant Flow System in EnergyPlus for Building Energy Simulation in an Open Building Information Modelling Environment
    Torregrosa-Jaime, Barbara
    Martinez, Pedro J.
    Gonzalez, Benjamin
    Paya-Ballester, Gaspar
    ENERGIES, 2019, 12 (01)
  • [3] Performance simulation of a joint solid desiccant heat pump and variable refrigerant flow air conditioning system in EnergyPlus
    Jiang, Yu
    Ge, Tianshu
    Wang, Ruzhu
    ENERGY AND BUILDINGS, 2013, 65 : 220 - 230
  • [4] Module development and energy simulation analysis of the variable refrigerant volume system based on energyplus
    Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240, China
    Xitong Fangzhen Xuebao, 2007, 20 (4808-4811):
  • [5] A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus
    Raustad, Richard
    ASHRAE TRANSACTIONS 2013, VOL 119, PT 1, 2013, 119 : 299 - 308
  • [6] Simulation and experimental validation of the variable-refrigerant-volume (VRV) air-conditioning system in EnergyPlus
    Zhou, Y. P.
    Wu, J. Y.
    Wang, R. Z.
    Shiochi, S.
    Li, Y. M.
    ENERGY AND BUILDINGS, 2008, 40 (06) : 1041 - 1047
  • [7] Variable flow and volume refrigerant system
    Goetzler, W
    Roth, KW
    Brodrick, J
    ASHRAE JOURNAL, 2004, 46 (01) : S164 - S165
  • [8] Energy Simulation of Integrated Multiple-Zone Variable Refrigerant Flow System
    Shen, Bo
    Rice, C. Keith
    McDowell, Timothy P.
    Baxter, Van D.
    2013 ASHRAE ANNUAL CONFERENCE, 2013,
  • [9] Energy simulation and analysis of the heat recovery variable refrigerant flow system in winter
    Li, Yue Ming
    Wu, Jing Yi
    ENERGY AND BUILDINGS, 2010, 42 (07) : 1093 - 1099
  • [10] Variable refrigerant flow
    Fiegen, Brian
    ASHRAE JOURNAL, 2007, 49 (06) : 8 - 8