RADIOTRACER EVALUATION OF THE DEPOSITION OF DRUG PARTICLES INHALED FROM A NEW POWDER INHALER

被引:10
|
作者
VIDGREN, M
PARONEN, P
VIDGREN, P
VAINIO, P
NUUTINEN, J
机构
[1] UNIV CENT HOSP KUOPIO,DEPT CLIN PHYSIOL,KUOPIO,FINLAND
[2] UNIV CENT HOSP,DEPT OTOLARYNGOL,KUOPIO,FINLAND
关键词
Asthma therapy; Deposition pattern; Disodium cromoglycate; Inhalation dosage form;
D O I
10.1016/0378-5173(90)90173-2
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Deposition of 99mTc-labelled particles of disodium cromoglycate in the human respiratory tract after inhalation either from the conventional metered dose aerosol or from the new Ingelheim powder inhaler (FO II) was compared. Fractional deposition in the whole lung area, in the upper airways and in the device was measured using a gamma camera. Eight healthy informed volunteers participated in the inhalation test. The lung deposition of the inhaled drug was about 9% using the conventional aerosol actuator with the short plastic mouthpiece whereas, using the Ingelheim powder inhaler, on average 20% deposition in the whole lung area was achieved. In addition, with the Ingelheim inhaler drug particles seemed to be deposited in the more peripheral parts of the respiratory tract. The upper airway deposition was also reduced with the Ingelheim powder inhaler. On the other hand, a larger fraction of the drug dose was retained in the Ingelheim inhaler than in the aerosol actuator. © 1990.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [41] Lung deposition of salbutamol in healthy human subjects from the MAGhaler dry powder inhaler
    Newman, S
    Malik, S
    Hirst, P
    Pitcairn, G
    Heide, A
    Pabst, J
    Dinkelaker, A
    Fleischer, W
    RESPIRATORY MEDICINE, 2002, 96 (12) : 1026 - 1032
  • [42] MEASUREMENT OF THE DEPOSITION AND CLEARANCE OF INHALED RADIOLABELED PARTICLES FROM RAT LUNGS
    NEWTON, PE
    PFLEDDERER, C
    JOURNAL OF APPLIED TOXICOLOGY, 1986, 6 (02) : 113 - 119
  • [43] Comparative in vitro performance of the new drug aclidinium in a novel multidose dry powder inhaler
    Gjaltema, Doetie
    Hagedoorn, Paul
    Grasmeijer, Floris
    Huijbers, Bernardus G.
    Frijlink, Henderik W.
    De Boer, Anne H.
    EUROPEAN RESPIRATORY JOURNAL, 2013, 42
  • [44] Detailed evaluation of drug powder deposition in swirl-type dry powder inhalers
    Sommerfeld, M.
    POWDER TECHNOLOGY, 2022, 407
  • [45] ALVEOLARIZATION OF TANTALUM POWDER IN EXPERIMENTAL BRONCHOGRAPHY AND CLEARANCE OF INHALED PARTICLES FROM LUNG
    FRIEDMAN, PJ
    TISI, GM
    RADIOLOGY, 1972, 104 (03) : 523 - &
  • [46] Extent of inhaled drug deposition at variable inhaler inclination angles and airway geometries: An in-vivo study from a novel computational fluid dynamics model
    Kuttler, Andreas
    Dimke, Thomas
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [47] In vivo lung deposition of hollow porous particles from a pressurized metered dose inhaler
    Hirst, PH
    Pitcairn, GR
    Weers, JG
    Tarara, TE
    Clark, AR
    Dellamary, LA
    Hall, G
    Shorr, J
    Newman, SP
    PHARMACEUTICAL RESEARCH, 2002, 19 (03) : 258 - 264
  • [48] Preparation and Evaluation of Surface Modified Lactose Particles for Improved Performance of Fluticasone Propionate Dry Powder Inhaler
    Singh, Deepak J.
    Jain, Rajesh R.
    Soni, P. S.
    Abdul, Samad
    Darshana, Hegde
    Gaikwad, Rajiv V.
    Menon, Mala D.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2015, 28 (04) : 254 - 267
  • [49] In Vivo Lung Deposition of Hollow Porous Particles from a Pressurized Metered Dose Inhaler
    Peter H. Hirst
    Gary R. Pitcairn
    Jeff G. Weers
    Thomas E. Tarara
    Andrew R. Clark
    Luis A. Dellamary
    Gail Hall
    Jolene Shorr
    Stephen P. Newman
    Pharmaceutical Research, 2002, 19 : 258 - 264
  • [50] PULMONARY DEPOSITION OF TC-99M-LABELED SALBUTAMOL PARTICLES IN HEALTHY-VOLUNTEERS AFTER INHALATION FROM A METERED-DOSE INHALER AND FROM A NOVEL MULTIPLE-DOSE POWDER INHALER
    VIDGREN, M
    ARPPE, J
    VIDGREN, P
    VAINIO, P
    SILVASTI, M
    TUKIAINEN, H
    STP PHARMA SCIENCES, 1994, 4 (01): : 29 - 32