RADIOTRACER EVALUATION OF THE DEPOSITION OF DRUG PARTICLES INHALED FROM A NEW POWDER INHALER

被引:10
|
作者
VIDGREN, M
PARONEN, P
VIDGREN, P
VAINIO, P
NUUTINEN, J
机构
[1] UNIV CENT HOSP KUOPIO,DEPT CLIN PHYSIOL,KUOPIO,FINLAND
[2] UNIV CENT HOSP,DEPT OTOLARYNGOL,KUOPIO,FINLAND
关键词
Asthma therapy; Deposition pattern; Disodium cromoglycate; Inhalation dosage form;
D O I
10.1016/0378-5173(90)90173-2
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Deposition of 99mTc-labelled particles of disodium cromoglycate in the human respiratory tract after inhalation either from the conventional metered dose aerosol or from the new Ingelheim powder inhaler (FO II) was compared. Fractional deposition in the whole lung area, in the upper airways and in the device was measured using a gamma camera. Eight healthy informed volunteers participated in the inhalation test. The lung deposition of the inhaled drug was about 9% using the conventional aerosol actuator with the short plastic mouthpiece whereas, using the Ingelheim powder inhaler, on average 20% deposition in the whole lung area was achieved. In addition, with the Ingelheim inhaler drug particles seemed to be deposited in the more peripheral parts of the respiratory tract. The upper airway deposition was also reduced with the Ingelheim powder inhaler. On the other hand, a larger fraction of the drug dose was retained in the Ingelheim inhaler than in the aerosol actuator. © 1990.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [31] Correction to: From indoor exposure to inhaled particle deposition: A multiphase journey of inhaled particles
    Kiao Inthavong
    Experimental and Computational Multiphase Flow, 2021, 3 : 322 - 322
  • [32] Lung Deposition of Aclidinium Bromide from Genuair®, a Multidose Dry Powder Inhaler
    Newman, S. P.
    Sutton, D. J.
    Segarra, R.
    Lamarca, R.
    de Miquel, G.
    RESPIRATION, 2009, 78 (03) : 322 - 328
  • [33] LUNG DEPOSITION OF SALBUTAMOL FROM THE LEIRAS METERED-DOSE POWDER INHALER
    PITCAIRN, GR
    LANKINEN, T
    VALKILA, E
    NEWMAN, SP
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1995, 8 (03): : 307 - 311
  • [34] A randomized trial of lower leg and height growth in children with asthma treated with inhaled budesonide from a new dry powder inhaler
    Gradman, Josefine
    Wolthers, Ole D.
    PEDIATRIC ALLERGY AND IMMUNOLOGY, 2010, 21 (01) : E206 - E212
  • [35] Comparison of the lung absorption of FK224 inhaled from a pressurized metered dose inhaler and a dry powder inhaler by healthy volunteers
    Nakate, T
    Yoshida, H
    Ohike, A
    Tokunaga, Y
    Ibuki, R
    Kawashima, Y
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2003, 56 (03) : 319 - 325
  • [36] THE BRONCHODILATOR RESPONSE FROM INCREASING DOSES OF TERBUTALINE INHALED FROM A MULTI-DOSE POWDER INHALER (TURBUHALER)
    PERSSON, G
    WIREN, JE
    EUROPEAN RESPIRATORY JOURNAL, 1990, 3 (01) : 24 - 26
  • [37] Dry powder inhaler design and particle technology in enhancing Pulmonary drug deposition: challenges and future strategies
    Islam, Nazrul
    Suwandecha, Tan
    Srichana, Teerapol
    DARU-JOURNAL OF PHARMACEUTICAL SCIENCES, 2024, 32 (02) : 761 - 779
  • [38] In Vitro Correlation Of Inhalational Acoustics From A Dry Powder Inhaler With Drug Delivery
    Seheult, J. N.
    O'Connell, P.
    Tee, K. C.
    Bholah, T.
    Sulaiman, I.
    D'Arcy, S.
    Holmes, M.
    Reilly, R.
    Ehrhardt, C.
    Healy, A. -M.
    Costello, R. W.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [39] Deposition and pharmacokinetics of budesonide from the Miat Monodose inhaler, a simple dry powder device
    Ball, DJ
    Hirst, PH
    Newman, SP
    Sonet, B
    Streel, B
    Vanderbist, F
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 245 (1-2) : 123 - 132
  • [40] Deposition of nacystelyn from a dry powder inhaler in healthy volunteers and cystic fibrosis patients
    Vanderbist, F
    Wery, B
    Baran, D
    Van Gansbeke, B
    Schoutens, A
    Moës, AJ
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2001, 27 (03) : 205 - 212